J 2017

Graphene and graphene oxide for biosensing

KUBESA, Ondřej, Veronika HORÁČKOVÁ, Zdeněk MORAVEC, Zdeněk FARKA, Petr SKLÁDAL et. al.

Základní údaje

Originální název

Graphene and graphene oxide for biosensing

Autoři

KUBESA, Ondřej (203 Česká republika, domácí), Veronika HORÁČKOVÁ (203 Česká republika, domácí), Zdeněk MORAVEC (203 Česká republika, domácí), Zdeněk FARKA (203 Česká republika, domácí) a Petr SKLÁDAL (203 Česká republika, garant, domácí)

Vydání

Monatshefte für Chemie - Chemical Monthly, Vienna, Springer, 2017, 0026-9247

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10403 Physical chemistry

Stát vydavatele

Rakousko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 1.285

Kód RIV

RIV/00216224:14740/17:00098076

Organizační jednotka

Středoevropský technologický institut

UT WoS

000413626000007

Klíčová slova anglicky

Biosensors; Electrochemistry; UV/Vis spectroscopy; Raman spectroscopy; Atomic force microscopy; Surface plasmon resonance

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 16. 3. 2018 14:26, prof. RNDr. Petr Skládal, CSc.

Anotace

V originále

Graphene-based nanomaterials attract large attention in electrochemistry due to their unique properties. Reliable method to modify electrodes by graphene is necessary to obtain desired improvement. In this work, different sizes of graphite flakes for preparation of graphene oxide (GO) were tested and the final characterization of the resulting GO was focused on a quick and reliable methods such as Raman and UV–Vis spectroscopy, atomic force microscopy, and surface plasmon resonance. Smaller particles resulted in bigger yield with higher stage of oxidation. Although the average thickness of GO was ~1 nm, differences between GO and by ascorbic acid chemically reduced GO were minimal in topography. The binding and stability of reduced GO on gold surface and gold modified by cysteamine were studied by surface plasmon resonance and cyclic voltammetry. The cysteamine provided slightly higher loading capacity compared to bare gold electrode; however, cyclic voltammetry proved that the electrochemical properties are identical, and therefore, cysteamine is not in this case necessary for GO immobilization.

Návaznosti

LQ1601, projekt VaV
Název: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
MUNI/A/1265/2015, interní kód MU
Název: Podpora biochemického výzkumu v roce 2016
Investor: Masarykova univerzita, Podpora biochemického výzkumu v roce 2016, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty