2017
Investigation of cis-trans isomer dependent dermatotoxicokinetics of UV filter ethylhexyl methoxycinnamate through stratum corneum in vivo
SHARMA, Anežka, Katarína BÁNYIOVÁ, Branislav VRANA, Ivan JUSTAN, Pavel ČUPR et. al.Základní údaje
Originální název
Investigation of cis-trans isomer dependent dermatotoxicokinetics of UV filter ethylhexyl methoxycinnamate through stratum corneum in vivo
Autoři
SHARMA, Anežka (203 Česká republika, domácí), Katarína BÁNYIOVÁ (703 Slovensko, domácí), Branislav VRANA (703 Slovensko, domácí), Ivan JUSTAN (203 Česká republika) a Pavel ČUPR (203 Česká republika, garant, domácí)
Vydání
Environmental Science and Pollution Research, HEIDELBERG, GERMANY, SPRINGER HEIDELBERG, 2017, 0944-1344
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10511 Environmental sciences
Stát vydavatele
Německo
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 2.800
Kód RIV
RIV/00216224:14310/17:00095511
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000414958700026
Klíčová slova anglicky
Ethylhexyl methoxycinnamate; Personal care products; Cis/trans isomerization; Tape stripping; Dermatotoxicokinetics; Human skin permeation
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 5. 4. 2018 15:36, Ing. Nicole Zrilić
Anotace
V originále
2-Ethylhexyl methoxycinnamate (EHMC) is one of the most used ultraviolet filters in personal care products. It undergoes cis/trans isomerization in sunlight, and there is limited toxicological understanding of the effects of the cis-isomer. It is known that two geometric isomers of one compound can have different physico-chemical properties and effects. However, there are no studies focusing on toxicokinetics of EHMC isomerization products to compare their potential difference in dermal exposure to cis-EHMC and trans-EHMC due to the difference in their dermatotoxicokinetics. In this study, dermal absorption of the parental trans-EHMC and its cis isomer was studied. A commercially available sunscreen lotion containing trans-EHMC and spiked with laboratory-prepared cis-EHMC was locally applied on the forearm skin of two volunteers. After 8 h of skin exposure, the stratum corneum (SC) layer was removed by tape stripping. The removed thickness of the SC was determined spectrophotometrically using a total protein assay. The concentration of both isomers in the removed SC was measured by HPLC-DAD. A new diffusion and permeability coefficient of both EHMC isomers in SC were determined by Fick's second law of diffusion in vivo. The difference in dermatotoxicokinetic parameters between the two isomers was not statistically significant. However, separate toxicological studies of isomeric forms and the determination of their dermatotoxicokinetic parameters are crucial for refinement of human risk assessment.
Návaznosti
GA14-27941S, projekt VaV |
| ||
LM2015051, projekt VaV |
| ||
LO1214, projekt VaV |
|