FARKA, Zdeněk, Matthias Jürgen MICKERT, Antonín HLAVÁČEK, Petr SKLÁDAL a Hans-Heiner GORRIS. Single-molecule upconversion-linked digital immunosensing of cancer biomarkers. In Biosensors 2018 - 28th Anniversary World Congress on Biosensors. 2018.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Single-molecule upconversion-linked digital immunosensing of cancer biomarkers
Autoři FARKA, Zdeněk, Matthias Jürgen MICKERT, Antonín HLAVÁČEK, Petr SKLÁDAL a Hans-Heiner GORRIS.
Vydání Biosensors 2018 - 28th Anniversary World Congress on Biosensors, 2018.
Další údaje
Originální jazyk angličtina
Typ výsledku Konferenční abstrakt
Obor 10406 Analytical chemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Organizační jednotka Středoevropský technologický institut
Klíčová slova anglicky single-molecule analysis; upconversion-linked immunosorbent assay; cancer biomarker; prostate specific antigen; photon-upconversion nanoparticle
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 26. 3. 2019 15:18.
Anotace
The ability to detect cancer biomarkers at the single-molecule level promises the ultimate sensitivity in clinical diagnosis. Fluorescence-based single-molecule analysis, however, is limited by matrix interferences, and therefore is typically not suitable for real world analytical applications. This optical background can be elegantly avoided by using photon-upconversion nanoparticles (UCNPs) that emit shorter-wavelength light under near-infrared (NIR) excitation (anti-Stokes emission). Conjugates of UCNPs with antibody can be used as a background-free luminescent tracer in upconversion-linked immunosensing. We have developed an optical approach for visualizing individual UCNPs by conventional epiluminescence microscopy and applied it for the sensitive detection of the cancer biomarker prostate specific antigen (PSA). Individual sandwich immunocomplexes consisting of (1) immobilized anti-PSA antibody, (2) PSA, and (3) anti-PSA antibody-UCNP conjugate were counted under an upconversion wide-field microscope equipped with a 980 nm laser excitation source. The noise-surpassing digital readout provided single particle resolution with almost no instrumental background. This allowed to reach a limit of detection (LOD) of 1.2 pg mL−1 (42 fM) of PSA in 25 % blood serum which is about ten times more sensitive than a classical (analog) readout of luminescence intensity.
Návaznosti
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
VytisknoutZobrazeno: 17. 8. 2024 18:14