ZIMA, Lukáš, Marta FARKOVÁ, Zdeněk FARKA a Přemysl LUBAL. Study of retention behavior of anions by ion chromatography. Online. In Libuše Trnková. XVIII. Workshop of Biophysical Chemists and Electrochemists. Brno: Masarykova univerzita, 2018, s. 72-73. ISBN 978-80-210-9029-3.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Study of retention behavior of anions by ion chromatography
Autoři ZIMA, Lukáš, Marta FARKOVÁ, Zdeněk FARKA a Přemysl LUBAL.
Vydání Brno, XVIII. Workshop of Biophysical Chemists and Electrochemists, od s. 72-73, 2 s. 2018.
Nakladatel Masarykova univerzita
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 10406 Analytical chemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Forma vydání elektronická verze "online"
WWW URL
Organizační jednotka Přírodovědecká fakulta
ISBN 978-80-210-9029-3
Klíčová slova anglicky Separation; Ion chromatography; Determination of anions; Analysis of drinking water
Změnil Změnil: doc. Mgr. Zdeněk Farka, Ph.D., učo 357740. Změněno: 15. 9. 2018 20:15.
Anotace
Ion chromatography (IC) belongs to the large group of separation methods that are based on separation of components in sample between two immiscible phases: mobile and stationary. In IC, the substances are separated due to different strengths of coulombic interactions with the stationary phase. Short analysis times, high separation efficiency, high reproducibility and low analysis costs make this technique useful in industry, clinical laboratories, food control and environmental analysis. This work is focused on the study of retention behavior of anions by IC and influence of experimental conditions (temperature, pH) on the separation efficiency. Mixtures of anions (F−, Cl−, NO2−, Br−, NO3−, PO43−, SO42− and I−) were analyzed on the Metrohm861 Advanced Compact IC ion chromatograph (Metrohm, Switzerland) with conductometric detector and Metrosep A Supp 4 - 250/4.0 annex column. The tested concentrations were in range of 0.08−10 mg/L. The analysis was performed with flow rate F of 1 ml/min, all samples were measured three times. The study of influence of temperature and pH on the separation was the main aim of this work. It was found that higher temperature and pH significantly decrease values of retention factors kA. The biggest difference was observed in case of iodide anions, where the retention time shifted from 22 to 14 min when the temperature was increased from 22 to 50 °C. The optimal analysis conditions were pH = 10.22 and t = 22 °C. The calibration provided LOD values between 3 μg/L (in case of Cl−) and 200 μg/L (in case of I−). To demonstrate the practical relevance of the method, real samples of drinking waters were analyzed. The achieved results were in good agreement with the concentration values declared by the producers. Ion chromatography represents a valuable approach for determination of anion concentrations. We have optimized the method with respect to effect of temperature and pH on the separation efficiency, the method is suitable for analysis of real samples. Due to discovered dependences it is possible to predict theoretical values of retention factors, which could be used to estimation of anion retention.
Návaznosti
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
MUNI/A/1237/2016, interní kód MUNázev: Vývoj metod a instrumentace pro analýzu biologicky významných látek 2017
Investor: Masarykova univerzita, Vývoj metod a instrumentace pro analýzu biologicky významných látek 2017, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
VytisknoutZobrazeno: 29. 7. 2024 07:20