2018
Prevention of benign stenosis due to endoluminal irreversible electroporation in bile ducts
ANDRAŠINA, Tomáš, Jiří PÁNEK, Dalibor ČERVINKA, Iva SVOBODOVÁ, Tomáš ROHAN et. al.Základní údaje
Originální název
Prevention of benign stenosis due to endoluminal irreversible electroporation in bile ducts
Autoři
ANDRAŠINA, Tomáš (703 Slovensko, domácí), Jiří PÁNEK (203 Česká republika, domácí), Dalibor ČERVINKA, Iva SVOBODOVÁ (203 Česká republika), Tomáš ROHAN (203 Česká republika, domácí), Jakub HUSTÝ (840 Spojené státy, domácí), Hiroko MARTIN (840 Spojené státy, domácí) a Vlastimil VÁLEK (203 Česká republika, domácí)
Vydání
CIRSE 2018, 2018
Další údaje
Jazyk
angličtina
Typ výsledku
Konferenční abstrakt
Obor
30224 Radiology, nuclear medicine and medical imaging
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 1.928
Kód RIV
RIV/00216224:14110/18:00103798
Organizační jednotka
Lékařská fakulta
ISSN
UT WoS
000446679300001
Klíčová slova anglicky
Irreversible electroporation; biodegradable stent; porcine model
Příznaky
Mezinárodní význam
Změněno: 31. 5. 2022 12:17, RNDr. Pavel Šmerk, Ph.D.
Anotace
V originále
Purpose To evaluate the possibility of preventing the formation of benign stenosis in healthy bile ducts due to endoluminal irreversible electroporation (IRE). Material and methods Endoluminal IRE of the common bile duct was performed on 15 porcine models using an endoluminal device inserted during laparotomy. The IRE procedure was conducted with 90 pulses of 900-1500 V. Models categorized in group A (n=5) underwent insertion of a biodegradable stent (30x10 mm, Ella-CS) in the ablation site. In group B, the ablation site of the models (n=10) remained untreated. All pigs were euthanized 22 days post-procedure. Biochemical liver tests and MRI were employed for follow-up on days 0, 3, and 22 after ablation. Results The IRE treatment and stent implantation was successful in all procedures. All animals survived over the defined study period. All biodegradable stents remained in place of ablation until the time of autopsy. In group A, serum bilirubin levels were slightly elevated immediately after the procedure (average 19.08 µmol/l compared to 8.33 µmol/l in group B). On day 22, significant elevation of serum bilirubin levels and AST levels were observed in group B (mean 1.73 µmol/l and 18.28 µmol/l, 0.79 µkat/l and 1.74 µkat/l in groups A and B respectively, p<0,05). MRCP sequence on day 22 showed mild or severe dilatation of intrahepatic biliary ducts in a majority of the models (n=9, 90%) in group B. By comparison, the image analysis in group A revealed no intrahepatic dilatation. Conclusion The preventive implantation of biodegradable stents following IRE of bile ducts should be a promising technique to deal with benign stenosis formation after treatment.