LATTA, Peter, Z. STARCUK, M.L.H. GRUWEL, Barbora LATTOVA, Petra LATTOVA, Pavel ŠTOURAČ a Boguslaw TOMANEK. Influence of k-space trajectory corrections on proton density mapping with ultrashort echo time imaging: Application for imaging of short T2 components in white matter. MAGNETIC RESONANCE IMAGING. NEW YORK: ELSEVIER SCIENCE INC, 2018, roč. 51, SEP, s. 87-95. ISSN 0730-725X. Dostupné z: https://dx.doi.org/10.1016/j.mri.2018.04.020. |
Další formáty:
BibTeX
LaTeX
RIS
@article{1443118, author = {Latta, Peter and Starcuk, Z. and Gruwel, M.L.H. and Lattova, Barbora and Lattova, Petra and Štourač, Pavel and Tomanek, Boguslaw}, article_location = {NEW YORK}, article_number = {SEP}, doi = {http://dx.doi.org/10.1016/j.mri.2018.04.020}, keywords = {Ultrashort T2; Gradient system imperfections; Ultrashort echo time (UTE); Quantitative MRI}, language = {eng}, issn = {0730-725X}, journal = {MAGNETIC RESONANCE IMAGING}, title = {Influence of k-space trajectory corrections on proton density mapping with ultrashort echo time imaging: Application for imaging of short T2 components in white matter}, url = {https://www.sciencedirect.com/science/article/pii/S0730725X18301036?via%3Dihub}, volume = {51}, year = {2018} }
TY - JOUR ID - 1443118 AU - Latta, Peter - Starcuk, Z. - Gruwel, M.L.H. - Lattova, Barbora - Lattova, Petra - Štourač, Pavel - Tomanek, Boguslaw PY - 2018 TI - Influence of k-space trajectory corrections on proton density mapping with ultrashort echo time imaging: Application for imaging of short T2 components in white matter JF - MAGNETIC RESONANCE IMAGING VL - 51 IS - SEP SP - 87-95 EP - 87-95 PB - ELSEVIER SCIENCE INC SN - 0730725X KW - Ultrashort T2 KW - Gradient system imperfections KW - Ultrashort echo time (UTE) KW - Quantitative MRI UR - https://www.sciencedirect.com/science/article/pii/S0730725X18301036?via%3Dihub N2 - Purpose: To evaluate the impact of MR gradient system imperfections and limitations for the quantitative mapping of short T2* signals performed by ultrashort echo time (UTE) acquisition approach. Materials and methods: The measurement of short T2* signals from a phantom and a healthy volunteer study (8 subjects of average age 28 4 years) were performed on a 3T scanner. The characteristics of the gradient system were obtained using calibration method performed directly on the measured subject or phantom. This information was used to calculate the actual sampling trajectory with the help of a parametric eddy current model. The actual sample positions were used to reconstruct corrected images and compared with uncorrected data. Results: Comparison of both approaches, i.e., without and with correction of k-space sampling trajectories revealed substantial improvement when correction was applied. The phantom experiments demonstrate substantial in-plane signal intensity variations for uncorrected sampling trajectories. In the case of the volunteer study, this led to significant differences in relative proton density (RPD) estimation between the uncorrected and corrected data (P = 0.0117 by Wilcoxon matched-pairs test) and provides for about 15% higher values for short T2* components of white matter (WM) in the case of uncorrected images. Conclusion: The imperfection of the applied gradients could induce errors in k-space data sampling which further propagates into the fidelity of the UTE images and jeopardizes precision of quantification. However, the study proved that measurement of gradient errors together with correction of sample positions can contribute to increased accuracy and unbiased characterization of short T2* signals. ER -
LATTA, Peter, Z. STARCUK, M.L.H. GRUWEL, Barbora LATTOVA, Petra LATTOVA, Pavel ŠTOURAČ a Boguslaw TOMANEK. Influence of k-space trajectory corrections on proton density mapping with ultrashort echo time imaging: Application for imaging of short T2 components in white matter. \textit{MAGNETIC RESONANCE IMAGING}. NEW YORK: ELSEVIER SCIENCE INC, 2018, roč.~51, SEP, s.~87-95. ISSN~0730-725X. Dostupné z: https://dx.doi.org/10.1016/j.mri.2018.04.020.
|