BEŇOVSKÁ, Miroslava, Ondřej WIEWIORKA a Jana PINKAVOVA. Evaluation of FUS-2000 urine analyzer: analytical properties and particle recognition. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION. ABINGDON: INFORMA HEALTHCARE, 2018, roč. 78, 1-2, s. 143-148. ISSN 0036-5513. Dostupné z: https://dx.doi.org/10.1080/00365513.2017.1423108.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Evaluation of FUS-2000 urine analyzer: analytical properties and particle recognition
Autoři BEŇOVSKÁ, Miroslava (203 Česká republika, garant, domácí), Ondřej WIEWIORKA (203 Česká republika, domácí) a Jana PINKAVOVA (203 Česká republika).
Vydání SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, ABINGDON, INFORMA HEALTHCARE, 2018, 0036-5513.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30100 3.1 Basic medicine
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 1.380
Kód RIV RIV/00216224:14110/18:00103986
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1080/00365513.2017.1423108
UT WoS 000424952600023
Klíčová slova anglicky Laboratory routines and automation; urinalysis; analytical performance; laboratory statistics; microscopy; medical biochemistry
Štítky 14110512, 14110616, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 9. 2. 2019 22:55.
Anotace
This study evaluates the performance of microscopic part of a hybrid analyzer FUS-2000 (Dirui Industrial Co., Changchun, China), its analytical properties and particle recognition. The evaluation of trueness, repeatability, detection limit, carry-over, linearity range and analytical stability was performed according to Dirui protocol guidelines designed by Dirui Company to guarantee the quality of the instrument. Trueness for low, medium and high-value concentrations was calculated with bias of 15.5, 4.7 and -6.6%, respectively. Detection limit of 5 Ery/l was confirmed. Coefficient of variation of 11.0, 5.2 and 3.8% was measured for within-run repeatability of low, medium and high concentration. Between-run repeatability for daily quality control had coefficient of variation of 3.0%. Carry-over did not exceed 0.05%. Linearity was confirmed for range of 0-16,000 particles/l (R-2=0.9997). The analytical stability had coefficient of variation of 4.3%. Out of 1258 analyzed urine samples, 362 positive were subjected to light microscopy urine sediment analysis and compared to the analyzer results. Cohen's kappa coefficients were calculated to express the concordance. Squared kappa coefficient was 0.927 (red blood cells), 0.888 (white blood cells), 0.908 (squamous epithelia), 0.634 (transitional epithelia), 0.628 (hyaline casts), 0.843 (granular casts) and 0.623 (bacteria). Single kappa coefficients were 0.885 (yeasts) and 0.756 (crystals), respectively. Aforementioned results show good analytical performance of the analyzer and tight agreement with light microscopy of urine sediment.