J 2018

Distribution and Mobility Potential of Trace Elements in the Main Seam of the Most Coal Basin

VÖRÖŠ, Dominik, Eva GERŠLOVÁ, Mercedes DÍAZ-SOMOANO, Ivana SÝKOROVÁ, Isabel SUÁREZ-RUIZ et. al.

Základní údaje

Originální název

Distribution and Mobility Potential of Trace Elements in the Main Seam of the Most Coal Basin

Autoři

VÖRÖŠ, Dominik (203 Česká republika), Eva GERŠLOVÁ (203 Česká republika), Mercedes DÍAZ-SOMOANO (724 Španělsko), Ivana SÝKOROVÁ (203 Česká republika), Isabel SUÁREZ-RUIZ (724 Španělsko), Martina HAVELCOVÁ (203 Česká republika) a Jan KUTA (203 Česká republika, garant, domácí)

Vydání

International Journal of Coal Geology, Elsevier, 2018, 0166-5162

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

20704 Energy and fuels

Stát vydavatele

Nizozemské království

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 5.330

Kód RIV

RIV/00216224:14310/18:00104565

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000445718300011

Klíčová slova anglicky

Holešice member; Lower bench; Mobility potential; Most Basin; Trace elements

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 2. 5. 2019 16:13, Mgr. Tereza Miškechová

Anotace

V originále

The Most Basin represents a coal basin with a long mining history in the Czech Republic. The majority of palaeo-environmental and geochemical studies have been focused on the upper part of the coal-bearing Most Formation where the coal is generally enriched in As, Cr, Ni, Cu and Zn. This study evaluated the distribution of V, Cr, Ni, Cu, Zn, Pb, Se, As, and Mn from the lower part. Regarding to the transport of inorganic elements into environment, the evaluation of mobility potential was also conducted. The total of 51 samples were collected from the Lower Bench in the Holesice Member. The chemical analyses were performed together with optical microscopy. The X-ray spectroscopy and ICP-MS were used to detect trace element contents in the study set of samples. 4 samples were subjected to the Sequential Extraction Procedure. The prepared leachates were analysed using the ICP-MS method. In total, 13 elements were screened in samples within the study profile. The mode of occurrence is the key factor for identifying a potential source of the trace elements. All evaluated trace elements (V, Cr, Ni, Cu, Zn, Pb, Se, As and Mn) leached most in the oxidisable fraction. On the other hand, As, Mn, Ni, Zn and Cd leached in more mobile fractions, e.g. reducible and acid.

Návaznosti

CZ.02.1.01/0.0/0.0/16_013/0001761, interní kód MU
Název: RECETOX RI - OP VVV (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, RECETOX RI - OP VVV, PO 1 Posilování kapacit pro kvalitní výzkum
LM2015051, projekt VaV
Název: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Výzkumná infrastruktura RECETOX