BOEDDINGHAUS, J., T. NESTELBERGER, R. TWERENBOLD, J.T. NEUMANN, B. LINDAHL, E. GIANNITSIS, N.A. SORENSEN, P. BADERTSCHER, J.E. JANN, D. WUSSLER, C. PUELACHER, M.R. GIMENEZ, K. WILDI, I. STREBEL, J.D. de LAVALLAZ, F. SELMAN, Z. SABTI, N. KOZHUHAROV, E. POTLUKOVA, K. RENTSCH, O. MIRO, F.J. MARTIN-SANCHEZ, B. MORAWIEC, Jiří PAŘENICA, J. LOHRMANN, W. KLOOS, A. BUSER, N. GEIGY, D.I. KELLER, S. OSSWALD, T. REICHLIN, D. WESTERMANN, S. BLANKENBERG a C. MUELLER. Impact of age on the performance of the ESC 0/1h-algorithms for early diagnosis of myocardial infarction. European heart journal. Oxford: Oxford University Press, 2018, roč. 39, č. 42, s. 3780-3794. ISSN 0195-668X. Dostupné z: https://dx.doi.org/10.1093/eurheartj/ehy514. |
Další formáty:
BibTeX
LaTeX
RIS
@article{1477961, author = {Boeddinghaus, J. and Nestelberger, T. and Twerenbold, R. and Neumann, J.T. and Lindahl, B. and Giannitsis, E. and Sorensen, N.A. and Badertscher, P. and Jann, J.E. and Wussler, D. and Puelacher, C. and Gimenez, M.R. and Wildi, K. and Strebel, I. and Lavallaz, J.D. de and Selman, F. and Sabti, Z. and Kozhuharov, N. and Potlukova, E. and Rentsch, K. and Miro, O. and MartinandSanchez, F.J. and Morawiec, B. and Pařenica, Jiří and Lohrmann, J. and Kloos, W. and Buser, A. and Geigy, N. and Keller, D.I. and Osswald, S. and Reichlin, T. and Westermann, D. and Blankenberg, S. and Mueller, C.}, article_location = {Oxford}, article_number = {42}, doi = {http://dx.doi.org/10.1093/eurheartj/ehy514}, keywords = {Age; High-sensitivity cardiac troponin; Guidelines; 0/1h-Algorithm; Diagnosis of AMI}, language = {eng}, issn = {0195-668X}, journal = {European heart journal}, title = {Impact of age on the performance of the ESC 0/1h-algorithms for early diagnosis of myocardial infarction}, volume = {39}, year = {2018} }
TY - JOUR ID - 1477961 AU - Boeddinghaus, J. - Nestelberger, T. - Twerenbold, R. - Neumann, J.T. - Lindahl, B. - Giannitsis, E. - Sorensen, N.A. - Badertscher, P. - Jann, J.E. - Wussler, D. - Puelacher, C. - Gimenez, M.R. - Wildi, K. - Strebel, I. - Lavallaz, J.D. de - Selman, F. - Sabti, Z. - Kozhuharov, N. - Potlukova, E. - Rentsch, K. - Miro, O. - Martin-Sanchez, F.J. - Morawiec, B. - Pařenica, Jiří - Lohrmann, J. - Kloos, W. - Buser, A. - Geigy, N. - Keller, D.I. - Osswald, S. - Reichlin, T. - Westermann, D. - Blankenberg, S. - Mueller, C. PY - 2018 TI - Impact of age on the performance of the ESC 0/1h-algorithms for early diagnosis of myocardial infarction JF - European heart journal VL - 39 IS - 42 SP - 3780-3794 EP - 3780-3794 PB - Oxford University Press SN - 0195668X KW - Age KW - High-sensitivity cardiac troponin KW - Guidelines KW - 0/1h-Algorithm KW - Diagnosis of AMI N2 - Aims We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific to older patients. Methods and results We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of and results acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age [<55 years (young), >= 55 to <70 years (middle-age), >= 70 years (old)]. Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% [95% confidence interval (95% CI) 94.9-100] in young, 99.3% (95% CI 96.0-99.9) in middle-age, and 99.3% (95% CI 97.599.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8-97.9) in young, 96.1% (95% CI 94.5-97.2) in middle-age, and 92.7% (95% CI 90.7-94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P <0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P< 0.01), reduced overall efficacy for hs-cTnT (P <0.01), while maintaining efficacy for hs-cTnl. Findings were confirmed in two validation cohorts (n = 2767). Conclusion While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnl. ER -
BOEDDINGHAUS, J., T. NESTELBERGER, R. TWERENBOLD, J.T. NEUMANN, B. LINDAHL, E. GIANNITSIS, N.A. SORENSEN, P. BADERTSCHER, J.E. JANN, D. WUSSLER, C. PUELACHER, M.R. GIMENEZ, K. WILDI, I. STREBEL, J.D. de LAVALLAZ, F. SELMAN, Z. SABTI, N. KOZHUHAROV, E. POTLUKOVA, K. RENTSCH, O. MIRO, F.J. MARTIN-SANCHEZ, B. MORAWIEC, Jiří PAŘENICA, J. LOHRMANN, W. KLOOS, A. BUSER, N. GEIGY, D.I. KELLER, S. OSSWALD, T. REICHLIN, D. WESTERMANN, S. BLANKENBERG a C. MUELLER. Impact of age on the performance of the ESC 0/1h-algorithms for early diagnosis of myocardial infarction. \textit{European heart journal}. Oxford: Oxford University Press, 2018, roč.~39, č.~42, s.~3780-3794. ISSN~0195-668X. Dostupné z: https://dx.doi.org/10.1093/eurheartj/ehy514.
|