2018
Preparative and capillary isoelectric focusing for detection and identification of Aspergillus conidia in complex sample matrices
HORKÁ, Marie, Jiří ŠALPLACHTA, Filip RŮŽIČKA a Karel ŠLAISZákladní údaje
Originální název
Preparative and capillary isoelectric focusing for detection and identification of Aspergillus conidia in complex sample matrices
Autoři
HORKÁ, Marie (203 Česká republika, garant), Jiří ŠALPLACHTA (203 Česká republika), Filip RŮŽIČKA (203 Česká republika, domácí) a Karel ŠLAIS (203 Česká republika)
Vydání
Journal of Separation Science, Germany, WILEY-V C H VERLAG GMBH, 2018, 1615-9306
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Německo
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.516
Kód RIV
RIV/00216224:14110/18:00106898
Organizační jednotka
Lékařská fakulta
UT WoS
000450408300013
Klíčová slova anglicky
capillary isoelectric focusing; peanuts; red pepper powder
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 21. 3. 2019 12:29, Soňa Böhmová
Anotace
V originále
This study describes a new method for fast identification of highly hydrophobic conidia of Aspergillus species from both simple and complex matrices. The method is based on recently developed preparative isoelectric focusing in a cellulose-based separation medium which had to be modified with respect to the highly hydrophobic surface of the conidia. Although Aspergillus conidia are colored, their zones in the cellulose bed were indicated by colored isoelectric point markers. The isoelectric point values of Aspergillus conidia were determined by capillary isoelectric focusing. Preparative isoelectric focusing was successfully used for preconcentration of individual conidia of cultivated strains of Aspergillus niger, Aspergillus fumigatus, Aspergillus flavus, and Aspergillus parasiticus, and also for separation of the conidia in a mixture. Subsequently, red pepper powder and peanuts spiked with Aspergillus niger and Aspergillus flavus conidia, respectively, were used as complex matrices. The detection limit for identification of the conidia in these complex matrices is 10(4) conidia mL(-1). The presence of conidia in the focused zones was confirmed by their subsequent analysis by capillary isoelectric focusing. Their viability was confirmed by a cultivation of the conidia extracted from the collected fractions after preparative isoelectric focusing.
Návaznosti
NV16-29916A, projekt VaV |
| ||
VI20172020069, projekt VaV |
|