LACINA, Karel, Jakub SOPOUŠEK, Veronika ČUNDERLOVÁ, Antonín HLAVÁČEK, Tomáš VÁCLAVEK a Veronika LACINOVÁ. Biosensing based on electrochemical impedance spectroscopy: Influence of the often-ignored molecular charge. ELECTROCHEMISTRY COMMUNICATIONS. NEW YORK: ELSEVIER SCIENCE INC, 2018, roč. 93, AUG, s. 183-186. ISSN 1388-2481. Dostupné z: https://dx.doi.org/10.1016/j.elecom.2018.07.015.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Biosensing based on electrochemical impedance spectroscopy: Influence of the often-ignored molecular charge
Autoři LACINA, Karel (203 Česká republika, garant, domácí), Jakub SOPOUŠEK (203 Česká republika, domácí), Veronika ČUNDERLOVÁ (203 Česká republika, domácí), Antonín HLAVÁČEK (203 Česká republika), Tomáš VÁCLAVEK (203 Česká republika, domácí) a Veronika LACINOVÁ (203 Česká republika).
Vydání ELECTROCHEMISTRY COMMUNICATIONS, NEW YORK, ELSEVIER SCIENCE INC, 2018, 1388-2481.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.197
Kód RIV RIV/00216224:14740/18:00101538
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1016/j.elecom.2018.07.015
UT WoS 000439858800040
Klíčová slova anglicky Biosensing; Immunosensing; Electrochemical impedance spectroscopy; Proteins; Positive charge
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 13. 3. 2019 12:54.
Anotace
When measurement of electrochemical impedance is used as an analytical method for affinity biosensors, its increase is in the most cases considered as a proof of specific binding. The increase of the mass in the protein layer is expected to be the cause. However, we encountered severe inconsistencies for these assumptions. In our experiments during the development of an immunosensor, proteins with diverse charges were immobilised and captured on the electrode surface. The measured values of impedance were predominantly affected by the charge of these proteins - negatively charged proteins caused (an expected) increase of the impedance values. Contrary, immobilization/capture of positively charged proteins and other compounds caused (a surprising) relative decrease of the impedance. The obvious and logical origin of this behaviour - a repulsive or attractive ionic interactions between protein layers and negatively charged redox probe [Fe(CN)(6)](4-/3-) (commonly used in electrochemistry) - is usually neglected throughout the literature although some fragmental information could be traced. Besides, we want to emphasize here the importance of the additional characterization of the studied system using for example gel electrophoresis, since many unexpected and overlooked factors can influence the electrochemical response upon analyte binding.
Návaznosti
GBP206/12/G014, projekt VaVNázev: Centrum pokročilých bioanalytických technologií
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020