2018
Graphene Oxide from Improved Hummers' Method: Is This Material Suitable for Reproducible Electrochemical (Bio)Sensing?
LACINA, Karel, Ondřej KUBESA, Veronika HORÁČKOVÁ, Zdeněk MORAVEC, Jan KUTA et. al.Základní údaje
Originální název
Graphene Oxide from Improved Hummers' Method: Is This Material Suitable for Reproducible Electrochemical (Bio)Sensing?
Autoři
LACINA, Karel (203 Česká republika, garant, domácí), Ondřej KUBESA (203 Česká republika, domácí), Veronika HORÁČKOVÁ (203 Česká republika, domácí), Zdeněk MORAVEC (203 Česká republika, domácí), Jan KUTA (203 Česká republika, domácí), Vanýsek PETR (203 Česká republika) a Petr SKLÁDAL (203 Česká republika, domácí)
Vydání
ECS Journal of Solid State Science and Technology, 2018, 2162-8769
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 1.795
Kód RIV
RIV/00216224:14740/18:00105948
Organizační jednotka
Středoevropský technologický institut
UT WoS
000446829400001
Klíčová slova anglicky
Graphene; Graphene Oxide; Improved Hummers' Method; Electrochemical (Bio)Sensing
Změněno: 23. 4. 2024 14:53, Mgr. Michal Petr
Anotace
V originále
Graphene as a superior nanomaterial is currently omnipresent and electroanalytical applications are not an exception. In this contribution, its suitability for such applications was critically assessed. We synthesized graphene oxide (GO) in five separate but identical experiments using the improved Hummers' method - well-known and extensively utilized procedure which is typically followed by various operations leading to reduced graphene oxide material. These five repeated trials were precisely controlled to keep the experimental conditions as identical as possible. The resulting five individual GO products were compared by means of elemental analysis, Raman spectroscopy, ICP-MS and AFM. The possible employment of such graphene products - electrochemically reduced GO - for electroanalytical purposes was also probed from the viewpoint of the reproducibility of modification of electrodes and the results seem disconcerting, indicating poor reproducibility. No similar study in reproducibility has been performed until now, since all previous reports always compared only different methods of preparation and only discrete experiments of preparation - repeatability has not been properly addressed.