J 2019

Comparison of noninvasive pulse transit time determined from Doppler aortic flow and multichannel bioimpedance plethysmography

SOUKUP, Ladislav, Jana HRUŠKOVÁ, Pavel JURÁK, Josef HALÁMEK, Eva ZÁVODNÁ et. al.

Základní údaje

Originální název

Comparison of noninvasive pulse transit time determined from Doppler aortic flow and multichannel bioimpedance plethysmography

Autoři

SOUKUP, Ladislav (203 Česká republika), Jana HRUŠKOVÁ (203 Česká republika, domácí), Pavel JURÁK (203 Česká republika, domácí), Josef HALÁMEK (203 Česká republika), Eva ZÁVODNÁ (203 Česká republika, garant, domácí), Ivo VISCOR (203 Česká republika), Magdalena MATEJKOVA (703 Slovensko) a Vlastimil VONDRA (203 Česká republika)

Vydání

Medical & Biological Engineering & Computing, Heidelberg, Springer Berlin Heidelberg, 2019, 0140-0118

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

20601 Medical engineering

Stát vydavatele

Německo

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 2.022

Kód RIV

RIV/00216224:14210/19:00109078

Organizační jednotka

Filozofická fakulta

UT WoS

000467746900015

Klíčová slova anglicky

Bioimpedance; Doppler ultrasound; Pulse wave velocity (PWV); Pulse transit time (PTT)

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 6. 3. 2020 10:40, MUDr. Bc. Eva Závodná, Ph.D.

Anotace

V originále

The main goal of this study was to make a comparison of aortic flow timing obtained by PW Doppler in four aortic sections with timing of - dZ/dt max obtained by bioimpedance measurement in nine locations on the thorax and neck. This knowledge is essential for determination of which bioimpedance channel could be used as a proximal for evaluation of pulse wave velocity (PWV) from the beginning of the ascending aorta or another aortic section. Time intervals between the Doppler flow and bioimpedance information (- dZ/dt max) were compared. It was found that the channel located on the left part of the neck is the most suitable as a proximal bioimpedance channel which corresponds to the aortic arch. This match is obtained with regard to the value of the time difference as well as inter-subject stability. This channel can be used as a proximal for evaluation of pulse wave velocity from the aortic arch to the desired distal target place in the body when distance between measured parts is known. The data from 35 volunteers with adequate signal quality were analyzed.

Návaznosti

MUNI/A/1157/2017, interní kód MU
Název: Kardiovaskulární systém napříč obory - od molekulární diagnostiky po klinická vyšetření (Akronym: KADIMOKLIN)
Investor: Masarykova univerzita, Kardiovaskulární systém napříč obory - od molekulární diagnostiky po klinická vyšetření, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty