2018
Sulfur determination in concrete samples using laser-induced breakdown spectroscopy and limestone standards
HRDLIČKA, Aleš, Jitka HEGROVÁ, Karel NOVOTNÝ, Viktor KANICKÝ, David PROCHAZKA et. al.Základní údaje
Originální název
Sulfur determination in concrete samples using laser-induced breakdown spectroscopy and limestone standards
Autoři
HRDLIČKA, Aleš (203 Česká republika, garant, domácí), Jitka HEGROVÁ (203 Česká republika), Karel NOVOTNÝ (203 Česká republika, domácí), Viktor KANICKÝ (203 Česká republika, domácí), David PROCHAZKA (203 Česká republika), Jan NOVOTNÝ (203 Česká republika), Pavlína MODLITBOVÁ (203 Česká republika), Lucia SLÁDKOVÁ (703 Slovensko), Pavel POŘÍZKA (203 Česká republika) a Jozef KAISER (203 Česká republika)
Vydání
Spectrochimica Acta, Part B: Atomic Spectroscopy, Oxford, Elsevier, 2018, 0584-8547
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 3.101
Kód RIV
RIV/00216224:14310/18:00106041
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000430033200002
Klíčová slova anglicky
Sulfur; Concrete; Limestone; Standard; Laser; Induced; Breakdown; Spectroscopy; Inductively coupled; Plasma; Mass spectrometry; Triple; Quadrupole
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 23. 4. 2024 14:13, Mgr. Michal Petr
Anotace
V originále
A LIBS equipment operating at 532 nm was optimized and used for sulfur determination in concrete samples. The influence of He atmosphere in a gas-tight chamber (1000-200 mbar) on S I 921.29 nm line sensitivity, signal-to-background and signal-to-noise ratio was studied at gate delays 100-2000 ns. Wide range of gate delays from 500 to about 1000 ns and pressures from several hundreds of mbar to the atmospheric pressure can be used for the desired detection of sulfur. The LIBS quantification was done using a simple calibration method. A synthetic limestone enriched by defined amounts of sodium sulfate was newly employed for direct quantification of S in concrete. This powder material was pressed into pellets and ablated with the LIBS system. The average content of sulfur as SO3 in the samples was 0.41-0.70 wt% by LIBS and 0.43-0.61 wt% by a reference standard procedure employing gravimetry and Inductively Coupled Plasma Triple Quad Mass Spectrometry (ICP-QQQMS). The uncertainty of the yielded LIBS results covers also the dispersion of the points in the calibration line and ranges from 16 to 28% at the probability level of 95%. The uncertainty of the ICP-QQQMS results was almost 10%. No correction on different signal response on the limestone and on the concrete was necessary. (C) 2018 Elsevier B.V. All rights reserved.
Návaznosti
LQ1601, projekt VaV |
|