BEDNAŘÍK, Antonín, Markéta MACHÁLKOVÁ, Eugene MOSKOVETS, Kateřina COUFALÍKOVÁ, Pavel KRÁSENSKÝ, Pavel HOUŠKA, Jiří KROUPA, Jarmila NAVRÁTILOVÁ, Jan ŠMARDA a Jan PREISLER. MALDI MS Imaging at Acquisition Rates Exceeding 100 Pixels per Second. Journal of the American Society for Mass Spectrometry. New York: Springer, 2019, roč. 30, č. 2, s. 289-298. ISSN 1044-0305. Dostupné z: https://dx.doi.org/10.1007/s13361-018-2078-8.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název MALDI MS Imaging at Acquisition Rates Exceeding 100 Pixels per Second
Autoři BEDNAŘÍK, Antonín (203 Česká republika, domácí), Markéta MACHÁLKOVÁ (203 Česká republika, domácí), Eugene MOSKOVETS (840 Spojené státy), Kateřina COUFALÍKOVÁ (203 Česká republika, domácí), Pavel KRÁSENSKÝ (203 Česká republika, domácí), Pavel HOUŠKA (203 Česká republika), Jiří KROUPA (203 Česká republika), Jarmila NAVRÁTILOVÁ (203 Česká republika, domácí), Jan ŠMARDA (203 Česká republika, domácí) a Jan PREISLER (203 Česká republika, garant, domácí).
Vydání Journal of the American Society for Mass Spectrometry, New York, Springer, 2019, 1044-0305.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW Full Text
Impakt faktor Impact factor: 3.255
Kód RIV RIV/00216224:14310/19:00107314
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1007/s13361-018-2078-8
UT WoS 000457210600011
Klíčová slova anglicky Mass spectrometry imaging; Laser beam scanning; MALDI; TOF; MSI; High throughput; Grid ion source; 3D cell aggregates; Spheroids; Colorectal adenocarcinoma
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. Mgr. Jan Preisler, Ph.D., učo 45329. Změněno: 25. 3. 2020 16:00.
Anotace
The practicality of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) applied to molecular imaging of biological tissues is limited by the analysis speed. Typically, a relatively low speed of stop-and-go micromotion of XY stages is considered as a factor substantially reducing the rate with which fresh sample material can be supplied to the laser spot. The sample scan rate in our laboratory-built high-throughput imaging TOF mass spectrometer was significantly improved through the use of a galvanometer-based optical scanner performing fast laser spot repositioning on a target plate. The optical system incorporated into the ion source of our MALDI TOF mass spectrometer allowed focusing the laser beam via a modified grid into a 10-m round spot. This permitted the acquisition of high-resolution MS images with a well-defined pixel size at acquisition rates exceeding 100pixel/s. The influence of selected parameters on the total MS imaging time is discussed. The new scanning technique was employed to display the distribution of an antitumor agent in 3D colorectal adenocarcinoma cell aggregates; a single MS image comprising 100x100pixels with 10-m lateral resolution was recorded in approximately 70s.
Návaznosti
GA15-05387S, projekt VaVNázev: Laserově desorpční hmotnostní spektrometrie pro analýzu molekul a nanočástic
Investor: Grantová agentura ČR, Laserově desorpční hmotnostní spektrometrie pro analýzu molekul a nanočástic
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
MUNI/G/0974/2016, interní kód MUNázev: Optimalizace cílené terapie kolorektálního karcinomu ovlivňováním účinnosti penetrace a cytotoxicity regulátorů buněčných signalizací
Investor: Masarykova univerzita, Optimalizace cílené terapie kolorektálního karcinomu ovlivňováním účinnosti penetrace a cytotoxicity regulátorů buněčných signalizací, INTERDISCIPLINARY - Mezioborové výzkumné projekty
VytisknoutZobrazeno: 19. 7. 2024 09:16