J 2019

Duodenum sparing technique of preventive stenting of biliary tract anastomosis in pigs

GROLICH, Tomáš, Michal CRHA, Tomáš ANDRAŠINA, Zdeněk KALA, Petr RAUŠER et. al.

Základní údaje

Originální název

Duodenum sparing technique of preventive stenting of biliary tract anastomosis in pigs

Autoři

GROLICH, Tomáš (203 Česká republika, domácí), Michal CRHA (203 Česká republika), Tomáš ANDRAŠINA (703 Slovensko, garant, domácí), Zdeněk KALA (203 Česká republika, domácí), Petr RAUŠER (203 Česká republika), Jan HLAVSA (203 Česká republika, domácí) a Martin POTRUSIL (203 Česká republika, domácí)

Vydání

Acta Veterinaria Brno, Brno, Veterinární a farmaceutická univerzita Brno, 2019, 0001-7213

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30212 Surgery

Stát vydavatele

Česká republika

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 0.566

Kód RIV

RIV/00216224:14110/19:00108486

Organizační jednotka

Lékařská fakulta

UT WoS

000509757500005

Klíčová slova anglicky

Biodegradable; Self-expandable stent; Anastomotic stricture; Biliary stenosis; Preventive stenting; Polydioxanone

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 18. 3. 2021 09:49, Mgr. Tereza Miškechová

Anotace

V originále

Aim The main aim of this study was to find out standardized method for preventive stenting of biliary tract anastomosis with biodegradable self-expandable stent from polydioxanone and evaluate function of the stent. Materials and methods This experimental study was performed in four pigs with follow up of eight weeks. Procedure was done under general anesthesia. The function of the stent was verified by by clinical stage, blood test, magnetic resonance cholangiopancreatography and necropsy. Results Our duodenum sparing technique was described in detail and photographically documented. All pigs finished follow up without clinical, laboratory or radiologic signs of biliary obstruction. Necropsy did not reveal complication of the procedure or anastomotic stricture. Conclusions In conclusion this study demonstrated simple new duodenum sparing method of transanastomotic insertion of biodegradable self-expandable stent from polydioxanone. We did not find any complication during follow up. This method will be used in our follow up study with extended experimental a control group of animals and longer follow up to verify the preventive function of this stent.

Návaznosti

NV15-32484A, projekt VaV
Název: Využití nových biotechnologií v prevenci a léčbě stenóz žlučových cest