VANÍČKOVÁ, Elena, Markéta HOLÁ, Karel RAPOUCH, David PAVLIŇÁK, Radka KOPECKÁ a Viktor KANICKÝ. LA-ICP-MS analysis of metal layers on samples of cultural heritage. Chemical Papers. Cham: SPRINGER INTERNATIONAL PUBLISHING AG, 2019, roč. 73, č. 12, s. 2923-2936. ISSN 2585-7290. Dostupné z: https://dx.doi.org/10.1007/s11696-019-00745-6. |
Další formáty:
BibTeX
LaTeX
RIS
@article{1549042, author = {Vaníčková, Elena and Holá, Markéta and Rapouch, Karel and Pavliňák, David and Kopecká, Radka and Kanický, Viktor}, article_location = {Cham}, article_number = {12}, doi = {http://dx.doi.org/10.1007/s11696-019-00745-6}, keywords = {Laser ablation; Inductively coupled plasma mass spectrometry; Depth profiling; X-ray fluorescence spectroscopy; Metal layer}, language = {eng}, issn = {2585-7290}, journal = {Chemical Papers}, title = {LA-ICP-MS analysis of metal layers on samples of cultural heritage}, url = {https://link.springer.com/article/10.1007/s11696-019-00745-6}, volume = {73}, year = {2019} }
TY - JOUR ID - 1549042 AU - Vaníčková, Elena - Holá, Markéta - Rapouch, Karel - Pavliňák, David - Kopecká, Radka - Kanický, Viktor PY - 2019 TI - LA-ICP-MS analysis of metal layers on samples of cultural heritage JF - Chemical Papers VL - 73 IS - 12 SP - 2923-2936 EP - 2923-2936 PB - SPRINGER INTERNATIONAL PUBLISHING AG SN - 25857290 KW - Laser ablation KW - Inductively coupled plasma mass spectrometry KW - Depth profiling KW - X-ray fluorescence spectroscopy KW - Metal layer UR - https://link.springer.com/article/10.1007/s11696-019-00745-6 L2 - https://link.springer.com/article/10.1007/s11696-019-00745-6 N2 - LA-ICP-MS (laser ablation inductively coupled plasma mass spectrometry) was applied as a semi-destructive method for the analysis of metal layers on samples of cultural heritage. The LA system operates at a wavelength of 193 nm with a pulse duration of 4 ns. The laser ablation was performed using spot mode with a diameter of 110 mu m. This method was developed using eight varied reference samples with a defined layer depth and composition. Four real samples of watch cases were analysed, and the layer composition and thickness were determined together with two test reference samples. The analytical results were compared with X-ray fluorescence spectroscopy analysis. The layer thickness was additionally determined by scanning electron microscopy on the cross section of selected samples. ER -
VANÍČKOVÁ, Elena, Markéta HOLÁ, Karel RAPOUCH, David PAVLIŇÁK, Radka KOPECKÁ a Viktor KANICKÝ. LA-ICP-MS analysis of metal layers on samples of cultural heritage. \textit{Chemical Papers}. Cham: SPRINGER INTERNATIONAL PUBLISHING AG, 2019, roč.~73, č.~12, s.~2923-2936. ISSN~2585-7290. Dostupné z: https://dx.doi.org/10.1007/s11696-019-00745-6.
|