J 2020

Electrochemical determination of insulin at CuNPs/chitosan-MWCNTs and CoNPs/chitosan-MWCNTs modified screen printed carbon electrodes

ŠIŠOLÁKOVÁ, Ivana, Jana HOVANCOVÁ, Renáta ORIŇAKOVÁ, Andrej ORIŇAK, Libuše TRNKOVÁ et. al.

Základní údaje

Originální název

Electrochemical determination of insulin at CuNPs/chitosan-MWCNTs and CoNPs/chitosan-MWCNTs modified screen printed carbon electrodes

Autoři

ŠIŠOLÁKOVÁ, Ivana (703 Slovensko), Jana HOVANCOVÁ (703 Slovensko), Renáta ORIŇAKOVÁ (703 Slovensko, garant), Andrej ORIŇAK (703 Slovensko), Libuše TRNKOVÁ (203 Česká republika, domácí), Iveta TŘÍSKOVÁ (203 Česká republika, domácí), Zdeněk FARKA (203 Česká republika, domácí), Matěj PASTUCHA (203 Česká republika, domácí) a Jozef RADOŇÁK (703 Slovensko)

Vydání

Journal of Electroanalytical Chemistry, Lausanne, Elsevier, 2020, 1572-6657

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Švýcarsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 4.464

Kód RIV

RIV/00216224:14310/20:00115315

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000519336100002

Klíčová slova anglicky

Insulin; Screen printed carbon electrodes; Copper nanoparticles; Cobalt nanoparticles; Electrochemical determination

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 10. 10. 2024 11:33, Ing. Monika Szurmanová, Ph.D.

Anotace

V originále

Transition metal nanoparticles can be considered as promising low cost materials for insulin oxidation catalysis. Combination of transition metal nanoparticles with multi walled carbon nanotubes (MWCNTs), which enlarges the active surface area of the electrode, can improve the analytical characteristics of electrodes. Two types of screen printed carbon electrodes (SPCEs) modified by the combination of copper (CuNPs) or cobalt (CoNPs) nanoparticles with chitosan and MWCNTs were prepared. In the effort to find the most suitable modification for electrochemical insulin determination, stability, analytical characteristics and selectivity of both electrode types were compared. The results proved better stability and analytical characteristics with no significant influence of interferences on insulin determination at CoNPs/chitosan-MWCNTs/SPCE. These electrodes provided low limit of detection (25 nM), high sensitivity (0.031 mA uM-1) and wide linear range (0.05 uM to 5 uM) for insulin determination. The stability of the CoNPs/chitosan-MWCNTs/SPCE was very high, with only 1.7% decrease of maximal current value after 50 measurements. Therefore, CoNPs/chitosan-MWCNTs/SPCE can be considered as the suitable modification for new electrochemical sensor for insulin determination, with better analytical characteristics in comparison with SPCE modification using MWCNTs, chitosan and CuNPs described in this study.

Návaznosti

LM2018127, projekt VaV
Název: Česká infrastruktura pro integrativní strukturní biologii (Akronym: CIISB)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Czech Infrastructure for Integrative Structural Biology
90127, velká výzkumná infrastruktura
Název: CIISB II