JIRIK, Radovan, Torfinn TAXT, Ondrej MACICEK, Michal BARTOS, Jiri KRATOCHVILA, Karel SOUČEK, Eva DRAZANOVA, Lucie KRATKA, Aleš HAMPL a Zenon, Jr. STARCUK. Blind deconvolution estimation of an arterial input function for small animal DCE-MRI. MAGNETIC RESONANCE IMAGING. NEW YORK: ELSEVIER SCIENCE INC, 2019, roč. 62, OCT 2019, s. 46-56. ISSN 0730-725X. Dostupné z: https://dx.doi.org/10.1016/j.mri.2019.05.024.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Blind deconvolution estimation of an arterial input function for small animal DCE-MRI
Autoři JIRIK, Radovan (203 Česká republika, garant), Torfinn TAXT (578 Norsko), Ondrej MACICEK (203 Česká republika), Michal BARTOS (203 Česká republika), Jiri KRATOCHVILA (203 Česká republika), Karel SOUČEK (203 Česká republika, domácí), Eva DRAZANOVA (203 Česká republika), Lucie KRATKA (203 Česká republika), Aleš HAMPL (203 Česká republika, domácí) a Zenon, Jr. STARCUK (203 Česká republika).
Vydání MAGNETIC RESONANCE IMAGING, NEW YORK, ELSEVIER SCIENCE INC, 2019, 0730-725X.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30224 Radiology, nuclear medicine and medical imaging
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.053
Kód RIV RIV/00216224:14110/19:00112960
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.mri.2019.05.024
UT WoS 000481725200006
Klíčová slova anglicky DCE-MRI; Blind deconvolution; Arterial input function
Štítky 14110517, podil, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 1. 4. 2020 14:15.
Anotace
Purpose: One of the main obstacles for reliable quantitative dynamic contrast-enhanced (DCE) MRI is the need for accurate knowledge of the arterial input function (AIF). This is a special challenge for preclinical small animal applications where it is very difficult to measure the AIF without partial volume and flow artifacts. Furthermore, using advanced pharmacokinetic models (allowing estimation of blood flow and permeability surface area product in addition to the classical perfusion parameters) poses stricter requirements on the accuracy and precision of AIF estimation. This paper addresses small animal DCE-MRI with advanced pharmacokinetic models and presents a method for estimation of the AIF based on blind deconvolution. Methods: A parametric AIF model designed for small animal physiology and use of advanced pharmacokinetic models is proposed. The parameters of the AIF are estimated using multichannel blind deconvolution. Results: Evaluation on simulated data show that for realistic signal to noise ratios blind deconvolution AIF estimation leads to comparable results as the use of the true AIF. Evaluation on real data based on DCE-MRI with two contrast agents of different molecular weights showed a consistence with the known effects of the molecular weight. Conclusion: Multi-channel blind deconvolution using the proposed AIF model specific for small animal DCE-MRI provides reliable perfusion parameter estimates under realistic signal to noise conditions.