JURAK, Pavel, Karol CURILA, Pavel LEINVEBER, Frits W. PRINZEN, Ivo VISCOR, Filip PLESINGER, Radovan SMISEK, Radka PROCHAZKOVA, Pavel OSMANCIK, Josef HALAMEK, Magdaléna MATEJKOVÁ, Jolana LIPOLDOVÁ, Miroslav NOVÁK, Roman PANOVSKÝ, Petr ANDRLA, Vlastimil VONDRA, Petr STROS, Jana VESELÁ a Dalibor HERMAN. Novel ultra-high-frequency electrocardiogram tool for the description of the ventricular depolarization pattern before and during cardiac resynchronization. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. HOBOKEN: WILEY, 2020, roč. 31, č. 1, s. 300-307. ISSN 1045-3873. Dostupné z: https://dx.doi.org/10.1111/jce.14299.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Novel ultra-high-frequency electrocardiogram tool for the description of the ventricular depolarization pattern before and during cardiac resynchronization
Autoři JURAK, Pavel (203 Česká republika, garant), Karol CURILA (203 Česká republika), Pavel LEINVEBER (203 Česká republika, domácí), Frits W. PRINZEN (528 Nizozemské království), Ivo VISCOR (203 Česká republika), Filip PLESINGER (203 Česká republika), Radovan SMISEK (203 Česká republika), Radka PROCHAZKOVA (203 Česká republika), Pavel OSMANCIK (203 Česká republika), Josef HALAMEK (203 Česká republika), Magdaléna MATEJKOVÁ (203 Česká republika), Jolana LIPOLDOVÁ (203 Česká republika, domácí), Miroslav NOVÁK (203 Česká republika, domácí), Roman PANOVSKÝ (203 Česká republika, domácí), Petr ANDRLA (203 Česká republika), Vlastimil VONDRA (203 Česká republika), Petr STROS (203 Česká republika), Jana VESELÁ (203 Česká republika) a Dalibor HERMAN (203 Česká republika).
Vydání JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, HOBOKEN, WILEY, 2020, 1045-3873.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.424 v roce 2019
Kód RIV RIV/00216224:14110/20:00115332
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1111/jce.14299
UT WoS 000501187800001
Klíčová slova anglicky biventricular pacing; cardiac resynchronization therapy; His-bundle pacing; ultra-high-frequency ECG; ventricular electrical dyssynchrony
Štítky 14110115, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 3. 3. 2021 09:09.
Anotace
Introduction The present study introduces a new ultra-high-frequency 14-lead electrocardiogram technique (UHF-ECG) for mapping ventricular depolarization patterns and calculation of novel dyssynchrony parameters that may improve the selection of patients and application of cardiac resynchronization therapy (CRT). Methods Components of the ECG in sixteen frequency bands within the 150 to 1000 Hz range were used to create ventricular depolarization maps. The maximum time difference between the UHF QRS complex centers of mass of leads V1 to V8 was defined as ventricular electrical dyssynchrony (e-DYS), and the duration at 50% of peak voltage amplitude in each lead was defined as the duration of local depolarization (Vd). Proof of principle measurements was performed in seven patients with left (left bundle branch block) and four patients with right bundle branch block (right bundle branch block) before and during CRT using biventricular and His-bundle pacing. Results The acquired activation maps reflect the activation sequence under the tested conditions. e-DYS decreased considerably more than QRS duration, during both biventricular pacing (-50% vs -8%) and His-bundle pacing (-77% vs -13%). While biventricular pacing slightly increased Vd, His-bundle pacing reduced Vd significantly (+11% vs -36%), indicating the contribution of the fast conduction system. Optimization of biventricular pacing by adjusting VV-interval showed a decrease of e-DYS from 102 to 36 ms with only a small Vd increase and QRS duration decrease. Conclusions The UHF-ECG technique provides novel information about electrical activation of the ventricles from a standard ECG electrode setup, potentially improving the selection of patients for CRT and application of CRT.