FAJKUS, M., J. NEDOMA, R. MARTINEK, J. BRABLIK, J. VANUS, M. NOVAK, S. ZABKA, V. VASINEK, P. HANZLIKOVA a Lubomír VOJTÍŠEK. MR Fully Compatible and Safe FBG Breathing Sensor: A Practical Solution for Respiratory Triggering. IEEE Access. PISCATAWAY: IEEE Xplore Digital Library, 2019, roč. 7, č. 2019, s. 123013-123025. ISSN 2169-3536. Dostupné z: https://dx.doi.org/10.1109/ACCESS.2019.2937624.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název MR Fully Compatible and Safe FBG Breathing Sensor: A Practical Solution for Respiratory Triggering
Autoři FAJKUS, M., J. NEDOMA, R. MARTINEK, J. BRABLIK, J. VANUS, M. NOVAK, S. ZABKA, V. VASINEK, P. HANZLIKOVA a Lubomír VOJTÍŠEK (203 Česká republika, garant, domácí).
Vydání IEEE Access, PISCATAWAY, IEEE Xplore Digital Library, 2019, 2169-3536.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10201 Computer sciences, information science, bioinformatics
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.745
Kód RIV RIV/00216224:14740/19:00113263
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1109/ACCESS.2019.2937624
UT WoS 000487832300005
Klíčová slova anglicky Magnetic resonance imaging (MRI); respiratory rate (RR); fiber-optic sensor; fiber Bragg grating (FBG); respiratory triggering
Štítky CF MAFIL, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 16. 3. 2020 10:38.
Anotace
This publication describes an original simple low-cost MR fully-compatible and safe fiber-optic breathing sensor (FOBS), which can be used for respiratory triggering and for monitoring the development of respiratory rate within the MR environment and can, thus, serve as prevention from the hyperventilation syndrome. The sensor is created by encapsulation of the Bragg grating into conventional nasal oxygen cannulas. The sensor is immune to minor patient movements, thus limiting movement artifacts to a minimum. Thanks to this fact it can be used for the retrospective/prospective respiratory gating. The sensor is immune to electromagnetic interference (EMI) and can thus be used in any magnetic field (1.5T, 3T, and 7T). The sensor prototype has been tested in both laboratory and real magnetic resonance (3T) environments relative to conventional pneumatic respiration references (PRR). The data measured were statistically evaluated using the objective Bland-Altman method (BAM) and the functionality of the proposed solution was confirmed. Respiratory Triggering functionality was confirmed by the radiologic doctors on the basis of analyzing images using the most used respiratory triggered T2 TSE 3D sequences and by objective method using the Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE).