SLAVIK, Jan, Josef SKOPALIK, Ivo PROVAZNÍK a Jaromir HUBALEK. Multi-Electrode Array with a Planar Surface for Cell Patterning by Microprinting. Sensors. Basel: MDPI, 2019, roč. 19, č. 24, s. 1-11. ISSN 1424-8220. Dostupné z: https://dx.doi.org/10.3390/s19245379.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Multi-Electrode Array with a Planar Surface for Cell Patterning by Microprinting
Autoři SLAVIK, Jan (203 Česká republika, garant), Josef SKOPALIK (203 Česká republika), Ivo PROVAZNÍK (203 Česká republika, domácí) a Jaromir HUBALEK (203 Česká republika).
Vydání Sensors, Basel, MDPI, 2019, 1424-8220.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10405 Electrochemistry
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.275
Kód RIV RIV/00216224:14110/19:00113322
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.3390/s19245379
UT WoS 000517961400043
Klíčová slova anglicky multielectrode array; microelectrode array; sacrificial layer; peel-off; HL-1 cells; microprinting; antifouling agent
Štítky 14110515, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 11. 5. 2020 11:18.
Anotace
Multielectrode arrays (MEAs) are devices for non-invasive electrophysiological measurements of cell populations. This paper describes a novel fabrication method of MEAs with a fully planar surface. The surface of the insulation layer and the surface of the electrodes were on one plane; we named this device the planar MEA (pMEA). The main advantage of the pMEA is that it allows uniform contact between the pMEA surface and a substrate for positioning of microfluidic channels or microprinting of a cell adhesive layer. The fabrication of the pMEA is based on a low adhesive Au sacrificial peel-off layer. In divergence from conventional MEAs with recessed electrodes, the electrodes of the pMEA lead across the sloped edge of the insulation layer. To make this, the profile of the edge of the insulation layer was measured and the impedance of the planar electrodes was characterized. The impedance of the pMEA was comparable with the impedance of conventional MEA electrodes. The pMEA was tested for patterning HL-1 cells with a combination of imprinting fibronectin and coating by antifouling poly (l-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG). The HL-1 cells remained patterned even at full confluency and presented spontaneous and synchronous beating activity.
Návaznosti
LM2015041, projekt VaVNázev: CEITEC Nano
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC Nano
VytisknoutZobrazeno: 27. 7. 2024 20:37