D 2019

Fast In Vivo High-Resolution Diffusion MRI of the Human Cervical Spinal Cord Microstructure

LABOUNEK, René, J. VALOSEK, J. ZIMOLKA, Z. PISKOROVA, Tomáš HORÁK et. al.

Základní údaje

Originální název

Fast In Vivo High-Resolution Diffusion MRI of the Human Cervical Spinal Cord Microstructure

Autoři

LABOUNEK, René (203 Česká republika), J. VALOSEK, J. ZIMOLKA, Z. PISKOROVA, Tomáš HORÁK (203 Česká republika, domácí), Alena SVÁTKOVÁ (703 Slovensko, domácí), Petr BEDNAŘÍK (203 Česká republika, domácí), P. HOK, Lubomír VOJTÍŠEK (203 Česká republika, domácí), P. HLUSTIK, Josef BEDNAŘÍK (203 Česká republika, garant, domácí) a C. LENGLET

Vydání

NEW YORK, WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, od s. 3-7, 5 s. 2019

Nakladatel

SPRINGER

Další údaje

Jazyk

angličtina

Typ výsledku

Stať ve sborníku

Obor

30103 Neurosciences

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Forma vydání

elektronická verze "online"

Kód RIV

RIV/00216224:14740/19:00108610

Organizační jednotka

Středoevropský technologický institut

ISBN

978-981-10-9034-9

ISSN

UT WoS

000450908300001

Klíčová slova anglicky

Diffusion MRI; HARDI; High-resolution imaging Cervical spinal cord

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 8. 10. 2024 08:26, Ing. Jana Kuchtová

Anotace

V originále

Diffusion Magnetic Resonance Imaging (dMRI) is a widely-utilized method for assessment of microstructural properties in the central nervous system i.e., the brain and spinal cord (SC). In the SC, almost all previous human studies utilized Diffusion Tensor Imaging (DTI), which cannot accurately model areas where white matter (WM) pathways cross or diverge. While High Angular Diffusion Resolution Imaging (HARDI) can overcome some of these limitations, longer acquisition times critically limit its applicability to clinical human studies. In addition, previous human HARDI studies have used limited spatial resolution, with typically a few slices and voxel size similar to 1 x 1 x 5 mm(3) being acquired in tens of minutes. Thus, we have optimized a novel fast HARDI protocol that allows collecting dMRI data at high angular and spatial resolutions in clinically-feasible time. Our data was acquired, using a 3T Siemens Prisma scanner, in less than 9 min. It has a total of 75 diffusion-weighted volumes and high spatial resolution of 0.67 x 0.67 x 3 mm(3) (after interpolation in Fourier space) covering the cervical segments C4-C6. Our preliminary results demonstrate applicability of our technique in healthy individuals with good correspondence between low fractional anisotropy (FA) gray matter areas from the dMRI scans, and the same regions delineated on T2-weighted MR images with spatial resolution of 0.35 x 0.35 x 2.5 mm(3). Our data also allows the detection of crossing fibers that were previously shown in vivo only in animal studies.

Návaznosti

NV18-04-00159, projekt VaV
Název: Využití pokročilých magneticko-rezonančních technik k odhalení patofyziologie a zlepšení diagnostiky a praktického managementu degenerativní komprese krční míchy
Investor: Ministerstvo zdravotnictví ČR, Využití pokročilých magneticko-rezonančních technik k objasnění patofyziologie a zlepšení diagnostiky a praktického managementu degenerativní komprese krční míchy
90062, velká výzkumná infrastruktura
Název: Czech-BioImaging