2019
Fast In Vivo High-Resolution Diffusion MRI of the Human Cervical Spinal Cord Microstructure
LABOUNEK, René, J. VALOSEK, J. ZIMOLKA, Z. PISKOROVA, Tomáš HORÁK et. al.Základní údaje
Originální název
Fast In Vivo High-Resolution Diffusion MRI of the Human Cervical Spinal Cord Microstructure
Autoři
LABOUNEK, René (203 Česká republika), J. VALOSEK, J. ZIMOLKA, Z. PISKOROVA, Tomáš HORÁK (203 Česká republika, domácí), Alena SVÁTKOVÁ (703 Slovensko, domácí), Petr BEDNAŘÍK (203 Česká republika, domácí), P. HOK, Lubomír VOJTÍŠEK (203 Česká republika, domácí), P. HLUSTIK, Josef BEDNAŘÍK (203 Česká republika, garant, domácí) a C. LENGLET
Vydání
NEW YORK, WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, od s. 3-7, 5 s. 2019
Nakladatel
SPRINGER
Další údaje
Jazyk
angličtina
Typ výsledku
Stať ve sborníku
Obor
30103 Neurosciences
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Forma vydání
elektronická verze "online"
Kód RIV
RIV/00216224:14740/19:00108610
Organizační jednotka
Středoevropský technologický institut
ISBN
978-981-10-9034-9
ISSN
UT WoS
000450908300001
Klíčová slova anglicky
Diffusion MRI; HARDI; High-resolution imaging Cervical spinal cord
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 8. 10. 2024 08:26, Ing. Jana Kuchtová
Anotace
V originále
Diffusion Magnetic Resonance Imaging (dMRI) is a widely-utilized method for assessment of microstructural properties in the central nervous system i.e., the brain and spinal cord (SC). In the SC, almost all previous human studies utilized Diffusion Tensor Imaging (DTI), which cannot accurately model areas where white matter (WM) pathways cross or diverge. While High Angular Diffusion Resolution Imaging (HARDI) can overcome some of these limitations, longer acquisition times critically limit its applicability to clinical human studies. In addition, previous human HARDI studies have used limited spatial resolution, with typically a few slices and voxel size similar to 1 x 1 x 5 mm(3) being acquired in tens of minutes. Thus, we have optimized a novel fast HARDI protocol that allows collecting dMRI data at high angular and spatial resolutions in clinically-feasible time. Our data was acquired, using a 3T Siemens Prisma scanner, in less than 9 min. It has a total of 75 diffusion-weighted volumes and high spatial resolution of 0.67 x 0.67 x 3 mm(3) (after interpolation in Fourier space) covering the cervical segments C4-C6. Our preliminary results demonstrate applicability of our technique in healthy individuals with good correspondence between low fractional anisotropy (FA) gray matter areas from the dMRI scans, and the same regions delineated on T2-weighted MR images with spatial resolution of 0.35 x 0.35 x 2.5 mm(3). Our data also allows the detection of crossing fibers that were previously shown in vivo only in animal studies.
Návaznosti
NV18-04-00159, projekt VaV |
| ||
90062, velká výzkumná infrastruktura |
|