NEVÍDALOVÁ, Hana, Lenka MICHALCOVÁ a Zdeněk GLATZ. Capillary electrophoresis-based immunoassay and aptamer assay: A review. Electrophoresis. Hoboken: Wiley, 2020, roč. 41, 7-8, s. 414-433. ISSN 0173-0835. Dostupné z: https://dx.doi.org/10.1002/elps.201900426.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Capillary electrophoresis-based immunoassay and aptamer assay: A review
Autoři NEVÍDALOVÁ, Hana (203 Česká republika, domácí), Lenka MICHALCOVÁ (203 Česká republika, domácí) a Zdeněk GLATZ (203 Česká republika, garant, domácí).
Vydání Electrophoresis, Hoboken, Wiley, 2020, 0173-0835.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.535
Kód RIV RIV/00216224:14310/20:00114103
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1002/elps.201900426
UT WoS 000511222500001
Klíčová slova anglicky Application; Aptamer; CE; Immunoassay; Microchip
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 20. 11. 2020 14:56.
Anotace
Over the last two decades, the group of techniques called affinity probe CE has been widely used for the detection and the determination of several types of biomolecules with high sensitivity. These techniques combine the low sample consumption and high separation power of CE with the selectivity of the probe to the target molecule. The assays can be defined according to the type of probe used: CE immunoassays, with an antibody as the probe, or aptamer-based CE, with an aptamer as the probe. Immunoassays are generally divided into homogeneous and heterogeneous groups, and homogeneous variant can be further performed in competitive or noncompetitive formats. Interacting partners are free in solution at homogeneous assay, as opposed to heterogeneous analyses, where one of them is immobilized onto a solid support. Highly sensitive fluorescence, chemiluminescence or electrochemical detections were typically used in this type of study. The use of the aptamers as probes has several advantages over antibodies such as shorter generation time, higher thermal stability, lower price, and lower variability. The aptamer-based CE technique was in practice utilized for the determination of proteins in biological fluids and environmentally or clinically important small molecules. Both techniques were also transferred to microchip. This review is focused on theoretical principles of these techniques and a summary of their applications in research.
Anotace česky
Článek je zaměřen na bopanalytická stanovení pomocí CE a afinitních značek - protilátek a aptamerů.
Návaznosti
GA19-08358S, projekt VaVNázev: Nové přístupy pro studium afinitních interakcí založené na kapilární elektroforéze
Investor: Grantová agentura ČR, Nove přístupy pro studium afinitních interakcí založené na kapilární elektroforéze
VytisknoutZobrazeno: 26. 4. 2024 18:13