2020
Capillary electrophoresis-based immunoassay and aptamer assay: A review
NEVÍDALOVÁ, Hana, Lenka MICHALCOVÁ a Zdeněk GLATZZákladní údaje
Originální název
Capillary electrophoresis-based immunoassay and aptamer assay: A review
Autoři
NEVÍDALOVÁ, Hana (203 Česká republika, domácí), Lenka MICHALCOVÁ (203 Česká republika, domácí) a Zdeněk GLATZ (203 Česká republika, garant, domácí)
Vydání
Electrophoresis, Hoboken, Wiley, 2020, 0173-0835
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10600 1.6 Biological sciences
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 3.535
Kód RIV
RIV/00216224:14310/20:00114103
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000511222500001
Klíčová slova anglicky
Application; Aptamer; CE; Immunoassay; Microchip
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 20. 11. 2020 14:56, Mgr. Marie Šípková, DiS.
V originále
Over the last two decades, the group of techniques called affinity probe CE has been widely used for the detection and the determination of several types of biomolecules with high sensitivity. These techniques combine the low sample consumption and high separation power of CE with the selectivity of the probe to the target molecule. The assays can be defined according to the type of probe used: CE immunoassays, with an antibody as the probe, or aptamer-based CE, with an aptamer as the probe. Immunoassays are generally divided into homogeneous and heterogeneous groups, and homogeneous variant can be further performed in competitive or noncompetitive formats. Interacting partners are free in solution at homogeneous assay, as opposed to heterogeneous analyses, where one of them is immobilized onto a solid support. Highly sensitive fluorescence, chemiluminescence or electrochemical detections were typically used in this type of study. The use of the aptamers as probes has several advantages over antibodies such as shorter generation time, higher thermal stability, lower price, and lower variability. The aptamer-based CE technique was in practice utilized for the determination of proteins in biological fluids and environmentally or clinically important small molecules. Both techniques were also transferred to microchip. This review is focused on theoretical principles of these techniques and a summary of their applications in research.
Česky
Článek je zaměřen na bopanalytická stanovení pomocí CE a afinitních značek - protilátek a aptamerů.
Návaznosti
GA19-08358S, projekt VaV |
|