2019
Changes of Body Composition and Bioimpedance During Pregnancy-Pilot Study in Czech Republic
HLUBIK, J., K. RADOCHA, L. LHOTSKA a Lukáš HRUBANZákladní údaje
Originální název
Changes of Body Composition and Bioimpedance During Pregnancy-Pilot Study in Czech Republic
Autoři
HLUBIK, J. (203 Česká republika), K. RADOCHA (203 Česká republika), L. LHOTSKA (203 Česká republika) a Lukáš HRUBAN (203 Česká republika, garant, domácí)
Vydání
NEW YORK, WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, od s. 917-920, 4 s. 2019
Nakladatel
SPRINGER
Další údaje
Jazyk
angličtina
Typ výsledku
Stať ve sborníku
Obor
20601 Medical engineering
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Forma vydání
elektronická verze "online"
Odkazy
Kód RIV
RIV/00216224:14110/19:00113748
Organizační jednotka
Lékařská fakulta
ISBN
978-981-10-9038-7
ISSN
UT WoS
000449742700169
Klíčová slova anglicky
Pregnancy; Bioimpedance; Body composition; Fat mass; TBW; Weight; Resistance
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 11. 5. 2020 11:22, Mgr. Tereza Miškechová
Anotace
V originále
Monitoring of specific physiological values during gestation process is a very important process. Body composition values and directly measured bioimpedance values however are currently not included into this monitoring although these values can help to track healthy process of gestation. In this work we are presenting new possible measurements of progress of body composition and electrical values during whole gestation process in Czech population. Bioelectrical resistance, reactance and body composition values were measured by BIA device Tanita MC 180 MA on 5, 50, 250 and 500 kHz. BIA measurements from 10 women were evaluated during second and third trimester of pregnancy. We discovered changes in directly measured electrical values and calculated values during a gestation period. Statistically significant increase was discovered in calculated body composition values: Weight (kg) (P = 0.005), Fat mass (kg) (P = 0.01), TBW (kg) (P = 0.005). Statistical significant (P = 0.05) decrease on all used frequencies was discovered in resistance and reactance values. Average decrease of resistance across all frequencies was 73.17 +/- 7.62 Omega which presented 11.92 +/- 0.07%. Results suggest that body composition values and especially directly measured values that are not equation dependent can give precise description for gestation process and can be used as one of the markers of healthy gestation process in future. Hence this measuring and evaluating of directly measured electrical values and body composition values can give us more information about gestation process.