D 2019

Changes of Body Composition and Bioimpedance During Pregnancy-Pilot Study in Czech Republic

HLUBIK, J., K. RADOCHA, L. LHOTSKA a Lukáš HRUBAN

Základní údaje

Originální název

Changes of Body Composition and Bioimpedance During Pregnancy-Pilot Study in Czech Republic

Autoři

HLUBIK, J. (203 Česká republika), K. RADOCHA (203 Česká republika), L. LHOTSKA (203 Česká republika) a Lukáš HRUBAN (203 Česká republika, garant, domácí)

Vydání

NEW YORK, WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, od s. 917-920, 4 s. 2019

Nakladatel

SPRINGER

Další údaje

Jazyk

angličtina

Typ výsledku

Stať ve sborníku

Obor

20601 Medical engineering

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Forma vydání

elektronická verze "online"

Odkazy

Kód RIV

RIV/00216224:14110/19:00113748

Organizační jednotka

Lékařská fakulta

ISBN

978-981-10-9038-7

ISSN

UT WoS

000449742700169

Klíčová slova anglicky

Pregnancy; Bioimpedance; Body composition; Fat mass; TBW; Weight; Resistance

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 11. 5. 2020 11:22, Mgr. Tereza Miškechová

Anotace

V originále

Monitoring of specific physiological values during gestation process is a very important process. Body composition values and directly measured bioimpedance values however are currently not included into this monitoring although these values can help to track healthy process of gestation. In this work we are presenting new possible measurements of progress of body composition and electrical values during whole gestation process in Czech population. Bioelectrical resistance, reactance and body composition values were measured by BIA device Tanita MC 180 MA on 5, 50, 250 and 500 kHz. BIA measurements from 10 women were evaluated during second and third trimester of pregnancy. We discovered changes in directly measured electrical values and calculated values during a gestation period. Statistically significant increase was discovered in calculated body composition values: Weight (kg) (P = 0.005), Fat mass (kg) (P = 0.01), TBW (kg) (P = 0.005). Statistical significant (P = 0.05) decrease on all used frequencies was discovered in resistance and reactance values. Average decrease of resistance across all frequencies was 73.17 +/- 7.62 Omega which presented 11.92 +/- 0.07%. Results suggest that body composition values and especially directly measured values that are not equation dependent can give precise description for gestation process and can be used as one of the markers of healthy gestation process in future. Hence this measuring and evaluating of directly measured electrical values and body composition values can give us more information about gestation process.