J 2020

Triple-pulse LIBS: laser-induced breakdown spectroscopy signal enhancement by combination of pre-ablation and re-heating laser pulses

PROCHAZKA, David, Pavel PORIZKA, Jan NOVOTNY, Aleš HRDLIČKA, Karel NOVOTNÝ et. al.

Základní údaje

Originální název

Triple-pulse LIBS: laser-induced breakdown spectroscopy signal enhancement by combination of pre-ablation and re-heating laser pulses

Autoři

PROCHAZKA, David (garant), Pavel PORIZKA, Jan NOVOTNY, Aleš HRDLIČKA (203 Česká republika, domácí), Karel NOVOTNÝ (203 Česká republika, domácí), Petr SPERKA a Jozef KAISER

Vydání

Journal of analytical atomic spectrometry, Cambridge, Royal Society of Chemistry, 2020, 0267-9477

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Velká Británie a Severní Irsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 4.023

Kód RIV

RIV/00216224:14310/20:00115595

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000514606000004

Klíčová slova anglicky

EMISSION ENHANCEMENT; INDUCED PLASMA; STEEL SAMPLES; SINGLE-PULSE; ALUMINUM; SENSITIVITY; IMPROVEMENT; LEAD; NANOPARTICLES; RESIDUES

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 5. 5. 2020 14:17, Mgr. Marie Šípková, DiS.

Anotace

V originále

The goal of this work is to examine the effect of a third additional laser pulse on orthogonal double-pulse laser-induced breakdown spectroscopy (DP LIBS). Namely, a pre-ablation laser pulse and re-heating laser pulse were combined into triple-pulse LIBS (3P LIBS) to achieve plasma emission enhancement. The experiment was designed with emphasis on causing minimal sample damage by utilizing nanosecond laser pulses. It means that the energy of ablation laser pulses was set to the minimal value for which the intensities of selected spectral lines were above the limits of detection. This energy as well as the energies of the pre-ablation and the re-heating laser pulses were kept constant for all experimental arrangements. The interpulse delays for both DP LIBS and for 3P LIBS configurations were optimized for signal enhancements. The 3P LIBS results showed up to 5-fold improvement of the signal to background ratio compared with both DP LIBS arrangements and up to 228-fold improvement in comparison to conventional SP LIBS. In addition, it has been shown that the spectral lines with a higher value of excitation energy prove higher enhancement in both DP LIBS and 3P LIBS configurations. To explain this effect, the dimensions of ablation craters were measured for each configuration using a 3D optical microscope and the temperature was determined from the slope of the Boltzmann plot. It was shown that the pre-ablation causes an increase of ablation crater dimensions and the re-heating increases the plasma temperature.

Návaznosti

LQ1601, projekt VaV
Název: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
MUNI/A/1375/2018, interní kód MU
Název: Výzkum a vývoj v analytické a fyzikální chemii
Investor: Masarykova univerzita, Výzkum a vývoj v analytické a fyzikální chemii, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty