PROCHAZKA, David, Pavel PORIZKA, Jan NOVOTNY, Aleš HRDLIČKA, Karel NOVOTNÝ, Petr SPERKA a Jozef KAISER. Triple-pulse LIBS: laser-induced breakdown spectroscopy signal enhancement by combination of pre-ablation and re-heating laser pulses. Journal of analytical atomic spectrometry. Cambridge: Royal Society of Chemistry, 2020, roč. 35, č. 2, s. 293-300. ISSN 0267-9477. Dostupné z: https://dx.doi.org/10.1039/c9ja00323a.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Triple-pulse LIBS: laser-induced breakdown spectroscopy signal enhancement by combination of pre-ablation and re-heating laser pulses
Autoři PROCHAZKA, David (garant), Pavel PORIZKA, Jan NOVOTNY, Aleš HRDLIČKA (203 Česká republika, domácí), Karel NOVOTNÝ (203 Česká republika, domácí), Petr SPERKA a Jozef KAISER.
Vydání Journal of analytical atomic spectrometry, Cambridge, Royal Society of Chemistry, 2020, 0267-9477.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.023
Kód RIV RIV/00216224:14310/20:00115595
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1039/c9ja00323a
UT WoS 000514606000004
Klíčová slova anglicky EMISSION ENHANCEMENT; INDUCED PLASMA; STEEL SAMPLES; SINGLE-PULSE; ALUMINUM; SENSITIVITY; IMPROVEMENT; LEAD; NANOPARTICLES; RESIDUES
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 5. 5. 2020 14:17.
Anotace
The goal of this work is to examine the effect of a third additional laser pulse on orthogonal double-pulse laser-induced breakdown spectroscopy (DP LIBS). Namely, a pre-ablation laser pulse and re-heating laser pulse were combined into triple-pulse LIBS (3P LIBS) to achieve plasma emission enhancement. The experiment was designed with emphasis on causing minimal sample damage by utilizing nanosecond laser pulses. It means that the energy of ablation laser pulses was set to the minimal value for which the intensities of selected spectral lines were above the limits of detection. This energy as well as the energies of the pre-ablation and the re-heating laser pulses were kept constant for all experimental arrangements. The interpulse delays for both DP LIBS and for 3P LIBS configurations were optimized for signal enhancements. The 3P LIBS results showed up to 5-fold improvement of the signal to background ratio compared with both DP LIBS arrangements and up to 228-fold improvement in comparison to conventional SP LIBS. In addition, it has been shown that the spectral lines with a higher value of excitation energy prove higher enhancement in both DP LIBS and 3P LIBS configurations. To explain this effect, the dimensions of ablation craters were measured for each configuration using a 3D optical microscope and the temperature was determined from the slope of the Boltzmann plot. It was shown that the pre-ablation causes an increase of ablation crater dimensions and the re-heating increases the plasma temperature.
Návaznosti
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
MUNI/A/1375/2018, interní kód MUNázev: Výzkum a vývoj v analytické a fyzikální chemii
Investor: Masarykova univerzita, Výzkum a vývoj v analytické a fyzikální chemii, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
VytisknoutZobrazeno: 12. 7. 2024 13:16