Další formáty:
BibTeX
LaTeX
RIS
@article{1675418, author = {Střelák, David and Filipovič, Jiří and JiménezandMoreno, Amaya and Carazo, Jose María and Sánchez Sorzano, Carlos Óscar}, article_location = {Switzerland}, article_number = {6}, doi = {http://dx.doi.org/10.3390/electronics9061040}, keywords = {cryo-em; movie alignment; acceleration; gpu; flexalign; cuda; autotuning; cufft; cufftadvisor}, language = {eng}, issn = {2079-9292}, journal = {Electronics}, title = {FlexAlign: An Accurate and Fast Algorithm for Movie Alignment in Cryo-Electron Microscopy}, url = {https://www.mdpi.com/2079-9292/9/6/1040}, volume = {9}, year = {2020} }
TY - JOUR ID - 1675418 AU - Střelák, David - Filipovič, Jiří - Jiménez-Moreno, Amaya - Carazo, Jose María - Sánchez Sorzano, Carlos Óscar PY - 2020 TI - FlexAlign: An Accurate and Fast Algorithm for Movie Alignment in Cryo-Electron Microscopy JF - Electronics VL - 9 IS - 6 SP - 1-25 EP - 1-25 PB - MDPI SN - 20799292 KW - cryo-em KW - movie alignment KW - acceleration KW - gpu KW - flexalign KW - cuda KW - autotuning KW - cufft KW - cufftadvisor UR - https://www.mdpi.com/2079-9292/9/6/1040 L2 - https://www.mdpi.com/2079-9292/9/6/1040 N2 - Cryogenic Electron Microscopy (Cryo-EM) has been established as one of the key players in Structural Biology. It can reconstruct a 3D model of the sample at the near-atomic resolution, which led to a Method of the year award by Nature, and the Nobel Prize in 2017. With the growing number of facilities, faster microscopes, and new imaging techniques, new algorithms are needed to process the so-called movies data produced by the microscopes in real-time, while preserving a high resolution and maximum of additional information. In this article, we present a new algorithm used for movie alignment, called FlexAlign. FlexAlign is able to correctly compensate for the shift produced during the movie acquisition on-the-fly, using the current generation of hardware. The algorithm performs a global and elastic local registration of the movie frames using Cross-Correlation and B-spline interpolation for high precision. We show that our execution time is compatible with real-time correction and that we preserve the high-resolution information up to high frequency. ER -
STŘELÁK, David, Jiří FILIPOVIČ, Amaya JIMÉNEZ-MORENO, Jose María CARAZO a Carlos Óscar SÁNCHEZ SORZANO. FlexAlign: An Accurate and Fast Algorithm for Movie Alignment in Cryo-Electron Microscopy. \textit{Electronics}. Switzerland: MDPI, 2020, roč.~9, č.~6, s.~1-25. ISSN~2079-9292. Dostupné z: https://dx.doi.org/10.3390/electronics9061040.
|