NĚMCOVÁ, Andrea, Martin VÍTEK a Marie NOVÁKOVÁ. Complex study on compression of ECG signals using novel single-cycle fractal-based algorithm and SPIHT. Scientific Reports. London: Nature Publishing Group, 2020, roč. 10, č. 1, s. 1-15. ISSN 2045-2322. Dostupné z: https://dx.doi.org/10.1038/s41598-020-72656-6.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Complex study on compression of ECG signals using novel single-cycle fractal-based algorithm and SPIHT
Autoři NĚMCOVÁ, Andrea (203 Česká republika, garant), Martin VÍTEK (203 Česká republika) a Marie NOVÁKOVÁ (203 Česká republika, domácí).
Vydání Scientific Reports, London, Nature Publishing Group, 2020, 2045-2322.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30105 Physiology
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.379
Kód RIV RIV/00216224:14110/20:00116568
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1038/s41598-020-72656-6
UT WoS 000577252400032
Klíčová slova anglicky ECG signals; single-cycle fractal-based algorithm; SPIHT
Štítky 14110515, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 29. 10. 2020 07:11.
Anotace
Compression of ECG signal is essential especially in the area of signal transmission in telemedicine. There exist many compression algorithms which are described in various details, tested on various datasets and their performance is expressed by different ways. There is a lack of standardization in this area. This study points out these drawbacks and presents new compression algorithm which is properly described, tested and objectively compared with other authors. This study serves as an example how the standardization should look like. Single-cycle fractal-based (SCyF) compression algorithm is introduced and tested on 4 different databases-CSE database, MIT-BIH arrhythmia database, High-frequency signal and Brno University of Technology ECG quality database (BUT QDB). SCyF algorithm is always compared with well-known algorithm based on wavelet transform and set partitioning in hierarchical trees in terms of efficiency (2 methods) and quality/distortion of the signal after compression (12 methods). Detail analysis of the results is provided. The results of SCyF compression algorithm reach up to avL=0.4460 bps and PRDN=2.8236%.