2020
HARDI-ZOOMit protocol improves specificity to microstructural changes in presymptomatic myelopathy
LABOUNEK, René, Jan VALOŠEK, Tomáš HORÁK, Alena SVÁTKOVÁ, Petr BEDNAŘÍK et. al.Základní údaje
Originální název
HARDI-ZOOMit protocol improves specificity to microstructural changes in presymptomatic myelopathy
Autoři
LABOUNEK, René (203 Česká republika), Jan VALOŠEK (203 Česká republika), Tomáš HORÁK (203 Česká republika, domácí), Alena SVÁTKOVÁ (703 Slovensko, domácí), Petr BEDNAŘÍK (203 Česká republika, domácí), Lubomír VOJTÍŠEK (203 Česká republika, domácí), Magda HORÁKOVÁ (203 Česká republika, domácí), Igor NESTRAŠIL (203 Česká republika), Christophe LENGLET (250 Francie), Julien COHEN-ADAD (124 Kanada), Josef BEDNAŘÍK (203 Česká republika, domácí) a Petr HLUŠTÍK (203 Česká republika)
Vydání
Scientific Reports, London, Nature Publishing Group, 2020, 2045-2322
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
30210 Clinical neurology
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 4.379
Kód RIV
RIV/00216224:14110/20:00116731
Organizační jednotka
Lékařská fakulta
UT WoS
000585841900010
Klíčová slova anglicky
HARDI-ZOOMit protocol; presymptomatic myelopathy
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 9. 10. 2024 11:49, Ing. Jana Kuchtová
Anotace
V originále
Diffusion magnetic resonance imaging (dMRI) proved promising in patients with non-myelopathic degenerative cervical cord compression (NMDCCC), i.e., without clinically manifested myelopathy. Aim of the study is to present a fast multi-shell HARDI-ZOOMit dMRI protocol and validate its usability to detect microstructural myelopathy in NMDCCC patients. In 7 young healthy volunteers, 13 age-comparable healthy controls, 18 patients with mild NMDCCC and 15 patients with severe NMDCCC, the protocol provided higher signal-to-noise ratio, enhanced visualization of white/gray matter structures in microstructural maps, improved dMRI metric reproducibility, preserved sensitivity (SE = 87.88%) and increased specificity (SP = 92.31%) of control-patient group differences when compared to DTI-RESOLVE protocol (SE = 87.88%, SP = 76.92%). Of the 56 tested microstructural parameters, HARDI-ZOOMit yielded significant patient-control differences in 19 parameters, whereas in DTI-RESOLVE data, differences were observed in 10 parameters, with mostly lower robustness. Novel marker the white-gray matter diffusivity gradient demonstrated the highest separation. HARDI-ZOOMit protocol detected larger number of crossing fibers (5–15% of voxels) with physiologically plausible orientations than DTI-RESOLVE protocol (0–8% of voxels). Crossings were detected in areas of dorsal horns and anterior white commissure. HARDI-ZOOMit protocol proved to be a sensitive and practical tool for clinical quantitative spinal cord imaging.
Návaznosti
LM2018140, projekt VaV |
| ||
NV18-04-00159, projekt VaV |
| ||
90062, velká výzkumná infrastruktura |
| ||
90129, velká výzkumná infrastruktura |
|