J 2020

Second-Generation Phosgene and Diphosgene Detection Tube

PITSCHMANN, Vladimír, Lukáš MATĚJOVSKÝ, Jiří ZEMAN, David VETCHÝ, Michal DYMÁK et. al.

Základní údaje

Originální název

Second-Generation Phosgene and Diphosgene Detection Tube

Autoři

PITSCHMANN, Vladimír (203 Česká republika), Lukáš MATĚJOVSKÝ (203 Česká republika, garant), Jiří ZEMAN (203 Česká republika, domácí), David VETCHÝ (203 Česká republika, domácí), Michal DYMÁK (203 Česká republika), Martin LOBOTKA (203 Česká republika), Sylvie PAVLOKOVÁ (203 Česká republika, domácí) a Zdeněk MORAVEC (203 Česká republika, domácí)

Vydání

Chemosensors, MDPI AG, 2020, 2227-9040

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30104 Pharmacology and pharmacy

Stát vydavatele

Švýcarsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 3.398

Kód RIV

RIV/00216224:14160/20:00118673

Organizační jednotka

Farmaceutická fakulta

UT WoS

000601457700001

Klíčová slova anglicky

detection tubes; chemosensor; visual and fluorescence detection; phosgene; composite pellets

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 18. 6. 2021 09:06, Mgr. Hana Hurtová

Anotace

V originále

We have developed a second-generation detection tube for colorimetric and fluorescence detection of phosgene and diphosgene in air. The tube is packed with pellets made of a mixture of microcrystalline cellulose and magnesium aluminum metasilicate treated with a suitable monoterpene (camphor, menthol) to increase porosity and specific surface area. We impregnated the pellets with a specific o-phenylenediamine-pyronin (PY-OPD) based reagent. The detector with this novel indication charge enables phosgene or diphosgene to be selectively and sensitively detected at concentrations lower than as would those posing acute health risk. Owing to the analytical colorimetric and, at the same time, fluorescence signal, the detector is very robust while featuring good sensitivity and variability. The colorimetric limits of detection were 0.3 mg/m3 (tristimulus colorimeter), resp. 5 mg/m3 (with the naked eye), fluorescence detection limits of 0.3 mg/m3 (with the naked eye), all at an air sample volume of 1 dm3. The response was practically immediate, acid vapors and gases, or diethyl chlorophosphate as a simulant of nerve warfare chemical agents, were disruptive.

Návaznosti

VI20192022172, projekt VaV
Název: Detekční trubičky druhé generace pro kontinuální a opakované monitorování nervově paralytických a jiných toxických látek
Investor: Ministerstvo vnitra ČR, Detekční trubičky druhé generace pro kontinuální a opakované monitorování nervově paralytických a jiných toxických látek