Influence of sample surface topography on laser ablation process
SALAJKOVÁ, Zita, Markéta HOLÁ, David PROCHÁZKA, Jakub ONDRÁČEK, David PAVLIŇÁK et. al.Základní údaje
Originální název
Influence of sample surface topography on laser ablation process
Autoři
SALAJKOVÁ, Zita (203 Česká republika), Markéta HOLÁ (203 Česká republika, garant, domácí), David PROCHÁZKA (203 Česká republika), Jakub ONDRÁČEK (203 Česká republika), David PAVLIŇÁK (203 Česká republika, domácí), Ladislav ČELKO (203 Česká republika), Filip GREGAR (203 Česká republika, domácí), Petr ŠPERKA, Pavel POŘÍZKA, Viktor KANICKÝ (203 Česká republika, domácí), Alessandro DE GIACOMO a Jozef KAISER
Vydání
Talanta, Amsterdam, Elsevier, 2021, 0039-9140
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10400 1.4 Chemical sciences
Stát vydavatele
Nizozemské království
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 6.556
Kód RIV
RIV/00216224:14310/21:00120799
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000589944000010
Klíčová slova anglicky
Laser ablation; LA-ICP-MS; Surface analysis; Surface topography; Fractionation
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 22. 2. 2023 15:30, Mgr. Marie Šípková, DiS.
Anotace
V originále
In this work we discuss how sample surface topography can significantly influence the laser ablation (LA) process and, in turn, the analytical response of the LA Inductively Coupled Plasma Mass Spectrometr y (LA-ICP-MS) method. Six different surface topographies were prepared on a certified aluminiu m alloy sample BAM 311 and SRM NIST 610 to investigate the phenomenon. A l l the samples were repetitively measured by LA-ICP-MS using a spot by spot analysis. The effect oflaserfluence in the range of 1-13 J/cm(2) was studied . For majority ofmeasured isotopes, the ICP-MS signal was amplified with roughening of the sample surface. A stronger effect was observed on the Al alloy sample, where the more than sixty-time enhancement was achieved in comparison to the polished surface of the sample. Since the effect of surface topography is different for each analyte, it can be stated that surface properties affect not only the ICP-MS response, but also elemental fractionation in LA . The presented results show that different surface topographies may lead to misleading data interpretation because even when applying ablation preshots, the signal of individual elements changes. The utmost care must be taken when preparing the surface for single shot analysis or chemical mapping. On the other hand, by roughening the sample surface, it is possible to significantly increase the sensitivity of the method for individual analytes and supress a matrix effect.