J 2020

A new simple approach to estimation of membrane capacitance from current responses to voltage clamp steps

ŠIMURDA, Jiří, Milena ŠIMURDOVÁ a Olga ŠVECOVÁ

Základní údaje

Originální název

A new simple approach to estimation of membrane capacitance from current responses to voltage clamp steps

Autoři

ŠIMURDA, Jiří (203 Česká republika, garant, domácí), Milena ŠIMURDOVÁ (203 Česká republika, domácí) a Olga ŠVECOVÁ (203 Česká republika, domácí)

Vydání

PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, OXFORD, PERGAMON-ELSEVIER SCIENCE LTD, 2020, 0079-6107

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10608 Biochemistry and molecular biology

Stát vydavatele

Velká Británie a Severní Irsko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 3.667

Kód RIV

RIV/00216224:14110/20:00118630

Organizační jednotka

Lékařská fakulta

UT WoS

000582745400004

Klíčová slova anglicky

Membrane capacitance; Square wave stimulation; Evaluation method

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 2. 12. 2020 11:31, Mgr. Tereza Miškechová

Anotace

V originále

A variety of techniques of cell capacitance measurement have been proposed and applied in cellular electrophysiology. They are mostly based on the evaluation of membrane current responses to small changes in the membrane voltage. One of the currently used approaches applies the least-squares fit of an exponential current decay in response to voltage clamped rectangular pulses. In this study, we propose an alternative simpler approach to evaluation of the exponential parts in the current responses to square wave stimulation and present preliminary results of membrane capacitance evaluation. It is based on the property of the exponential function that has not yet been used to measure membrane capacitance. The time constant and the asymptote of the exponential waveform are unambiguously determined by the values read at three points separated by a constant time interval. In order to minimize the effect of noise and deviations from the exponential waveform, the triplet of points is designed to slide along the time axis. The results of the proposed approach and those previously evaluated by the least squares method are comparable. The method described may be advantageous for continuously recording changes in membrane capacitance. (C) 2020 Elsevier Ltd. All rights reserved.

Návaznosti

NV16-30571A, projekt VaV
Název: Klinický význam a elektrofyziologické zhodnocení mutace c.926C>T genu KCNQ1 (p.T309I) jako možné „founder mutation“ syndromu dlouhého intervalu QT