2020
A novel accurate LC-MS/MS method for quantitative determination of Z-lumirubin
JASPROVA, Jana, Ales DVORAK, Marek VECKA, Martin LENICEK, Ondrej LACINA et. al.Základní údaje
Originální název
A novel accurate LC-MS/MS method for quantitative determination of Z-lumirubin
Autoři
JASPROVA, Jana (203 Česká republika), Ales DVORAK (203 Česká republika), Marek VECKA (203 Česká republika), Martin LENICEK (203 Česká republika), Ondrej LACINA (203 Česká republika), Petra VALASKOVA (203 Česká republika), Milos ZAPADLO (203 Česká republika), Richard PLAVKA (203 Česká republika), Petr KLÁN (203 Česká republika, garant, domácí) a Libor VITEK (203 Česká republika)
Vydání
Scientific reports, LONDON, NATURE PUBLISHING GROUP, 2020, 2045-2322
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10700 1.7 Other natural sciences
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 4.379
Kód RIV
RIV/00216224:14310/20:00117827
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000563374600009
Klíčová slova anglicky
bilirubin; lumirubin; liquid chromatography; clinical use
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 17. 2. 2023 21:19, Mgr. Michaela Hylsová, Ph.D.
Anotace
V originále
Although phototherapy (PT) is a standard treatment for neonatal jaundice, no validated clinical methods for determination of bilirubin phototherapy products are available. Thus, the aim of our study was to establish a such method for clinical use. To achieve this aim, a LC-MS/MS assay for simultaneous determination of Z-lumirubin (LR) and unconjugated bilirubin (UCB) was conducted. LR was purified after irradiation of UCB at 460 nm. The assay was tested on human sera from PT-treated neonates. Samples were separated on a HPLC system with a triple quadrupole mass spectrometer detector. The instrument response was linear up to 5.8 and 23.4 mg/dL for LR and UCB, respectively, with submicromolar limits of detection and validity parameters relevant for use in clinical medicine. Exposure of newborns to PT raised serum LR concentrations three-fold (p < 0.01), but the absolute concentrations were low (0.37 +/- 0.16 mg/dL), despite a dramatic decrease of serum UCB concentrations (13.6 +/- 2.2 vs. 10.3 +/- 3.3 mg/dL, p < 0.01). A LC-MS/MS method for the simultaneous determination of LR and UCB in human serum was established and validated for clinical use. This method should help to monitor neonates on PT, as well as to improve our understanding of both the kinetics and biology of bilirubin phototherapy products.
Návaznosti
NV18-07-00342, projekt VaV |
|