SVOBODA, Antonín, Michal CHALUPA a Taťána ŠRÁMKOVÁ. Mechanical Medical Device for Generating Vibration and Stimulation of the Neuron Pathways. Symmetry. Basel: MDPI, 2021, roč. 13, č. 1, s. 1-11. ISSN 2073-8994. Dostupné z: https://dx.doi.org/10.3390/sym13010062.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Mechanical Medical Device for Generating Vibration and Stimulation of the Neuron Pathways
Autoři SVOBODA, Antonín (203 Česká republika, garant), Michal CHALUPA (203 Česká republika) a Taťána ŠRÁMKOVÁ (203 Česká republika, domácí).
Vydání Symmetry, Basel, MDPI, 2021, 2073-8994.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 20601 Medical engineering
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.940
Kód RIV RIV/00216224:14110/21:00120989
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.3390/sym13010062
UT WoS 000610770400001
Klíčová slova anglicky paralysis; reflex ejaculation; vibrostimulation; crank mechanism; accumulator; electrical motors; electrical motor regulator
Štítky 14110711, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 16. 2. 2021 13:43.
Anotace
This article describes a medical device uses precisely generated vibrations to obtain genetic material (sperm) in injured men, tetraplegics, and paraplegics. A significant advantage is the absence of general anesthesia of the patient. The DC motor of a medical device works with a safe voltage powered by rechargeable or AA cells. The principle of generation of vibration is a crank mechanism. Rotation of the flywheel is converted to rectilinear reciprocating motion. The amplitude is set in the range between 1–4 mm and the frequency is controlled by the RPM of the DC motor. If the stimulation will be followed preciously with the methodology, the process will be completed within 12 min from the beginning of stimulation. The success rate of the device is in the range between 65–85% depending on the patient’s condition and the extent of the spinal cord lesion. The measurement of sinusoidal oscillations was performed by using a stand in which the device was mounted. The amplitude was measured with an accelerometer and then mathematically converted by software Matlab and MS-Excel to the magnitude of the deviation in mm. Measurements have shown that the proposed design meets the requirements for amplitude and frequency.