NEDOMA, J., R. MARTINEK, M. FAJKUS, J. BRABLIK, R. KAHANKOVA, M. FRIDRICH, M. KOSTELANSKY, P. HANZLIKOVA, Lubomír VOJTÍŠEK a K. BEHBEHANI. A Novel FBG-Based Triggering System for Cardiac MR Imaging at 3 Tesla: A Pilot Pre-Clinical Study. IEEE Access. PISCATAWAY: IEEE Xplore Digital Library, 2020, roč. 8, č. 2020, s. 181205-181223. ISSN 2169-3536. Dostupné z: https://dx.doi.org/10.1109/ACCESS.2020.3028224.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název A Novel FBG-Based Triggering System for Cardiac MR Imaging at 3 Tesla: A Pilot Pre-Clinical Study
Autoři NEDOMA, J., R. MARTINEK, M. FAJKUS, J. BRABLIK, R. KAHANKOVA, M. FRIDRICH, M. KOSTELANSKY, P. HANZLIKOVA, Lubomír VOJTÍŠEK (203 Česká republika, garant, domácí) a K. BEHBEHANI.
Vydání IEEE Access, PISCATAWAY, IEEE Xplore Digital Library, 2020, 2169-3536.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10201 Computer sciences, information science, bioinformatics
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.367
Kód RIV RIV/00216224:14740/20:00118190
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1109/ACCESS.2020.3028224
UT WoS 000577884000001
Klíčová slova anglicky Electrocardiography; Heart; Magnetic resonance imaging; Fiber gratings; Monitoring; Fiber Bragg grating (FBG); optic system; cardiac triggering; electrocardiography (ECG); pulse oximetry (POX); magnetic resonance imaging (MRI)
Štítky CF MAFIL, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 12. 5. 2021 12:48.
Anotace
This first-ever study demonstrates the applicability of a fiber Bragg grating (FBG) system for MR cardiac triggering of cardiovascular magnetic resonance at 3 Tesla. The unique patented system senses body movements caused by cardiac activity using a non-invasive ballistocardiography (BCG) sensor. The pilot research compares a novel FBG-based system with clinically used triggering systems based on electrocardiography (ECG) and pulse oximetry (POX). The pilot pre-clinical study was conducted on 8 subjects at a Siemens Prisma 3T MR Scanner. The study compares images from two basic cardiac sequences, TRUE FISP (Free Induction Decay Steady-State Precession) and PSIR (Phase Sensitive Inversion Recovery), using objective methods and subjective evaluation by clinical experts. The study presents original results that confirm the applicability of optical sensors in the field of cardiac triggering having a number of advantages in comparison to conventional solutions, such as no eddy current interference, ease of placement of the sensor on the patient's body, and senor reusability. The proposed FBG-based system achieves comparable results with the most frequently used and most accurate ECG-based and POX-based clinical systems. In terms of subjective evaluation by experts, the FBG system outperformed the POX-based system used in clinical practice.
Návaznosti
LM2018129, projekt VaVNázev: Národní infrastruktura pro biologické a medicínské zobrazování Czech-BioImaging
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, National research infrastructure for biological and medical imaging
VytisknoutZobrazeno: 24. 7. 2024 10:21