JÍLKOVÁ, Simona Rozárka, Lisa Emily MELYMUK a Jana KLÁNOVÁ. Emerging investigator series: air conditioning filters as a sampler for semi-volatile organic compounds in indoor and near-building air. Environmental Science: Processes and Impacts. Cambridge: Royal Society of Chemistry, 2020, roč. 22, č. 12, s. 2322-2331. ISSN 2050-7887. Dostupné z: https://dx.doi.org/10.1039/d0em00284d.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Emerging investigator series: air conditioning filters as a sampler for semi-volatile organic compounds in indoor and near-building air
Autoři JÍLKOVÁ, Simona Rozárka (203 Česká republika, domácí), Lisa Emily MELYMUK (124 Kanada, garant, domácí) a Jana KLÁNOVÁ (203 Česká republika, domácí).
Vydání Environmental Science: Processes and Impacts, Cambridge, Royal Society of Chemistry, 2020, 2050-7887.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10511 Environmental sciences
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.238
Kód RIV RIV/00216224:14310/20:00114763
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1039/d0em00284d
UT WoS 000599425400003
Klíčová slova anglicky Halogenated Diphenyl Ethers; Hexabromocyclododecane; Tribromodiphenyl Ether 28
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 9. 3. 2021 15:53.
Anotace
Organic compounds like flame retardants (FRs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polycyclic aromatic hydrocarbons (PAHs) are consistently found in both indoor and outdoor environments. There are many possible matrices for measurement of these compounds (e.g. indoor dust, air - passive and active air samples), but all methods have limitations, like the heterogeneous distribution of indoor dust, or noisy active air samplers. We used filters from building-wide heating, ventilation and air conditioning (HVAC) units to evaluate levels of PAHs, PCBs, OCPs and NFRs in indoor and outdoor environments, and to evaluate whether this method is feasible for screening semivolatile organic compounds (SVOCs) in indoor and near-building outdoor environments. Detectable levels of FRs, PCBs, OCPs and PAHs were found, demonstrating that HVAC filters do collect SVOCs, with generally higher levels of PAHs in the incoming air filters and higher levels of PCBs, OCPs and FRs in the outgoing air filters. Levels of FRs, PCBs and OCPs in outgoing air were comparable to those measured using conventional active air sampling in the same building. The advantages of using HVAC filters are (1) integrated and homogeneous samples, as the whole building is sampled over typically a long timescale (months), and (2) samples are easy and cheap to collect and do not require prior deployment of samplers. The key disadvantage is that HVAC filters are not designed for analytical chemistry and thus the filter materials can have variable or unknown gas sorption and particle capture, and can have strong matrix effects during analysis.
Návaznosti
GA19-20479S, projekt VaVNázev: Prach jako významný zdroj expozice člověka endokrinním disruptorům ve vnitřním protředí
Investor: Grantová agentura ČR, Prach v prostředí jako důležitá expoziční cesta člověka působení endokrinních disruptorů
LM2018121, projekt VaVNázev: Výzkumná infrastruktura RECETOX (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, RECETOX RI
VytisknoutZobrazeno: 29. 7. 2024 22:25