Další formáty:
BibTeX
LaTeX
RIS
@inproceedings{1760256, author = {Košťál, Michal and Schulc, Martin and Novák, Evžen and Czakoj, Tomáš and Matěj, Zdeněk and Cvachovec, František and Mravec, Filip and Bohumil, Jánský and Leal, Luiz}, address = {Francie}, booktitle = {ND 2019: International Conference on Nuclear Data for Science and Technology}, doi = {http://dx.doi.org/10.1051/epjconf/202023918008}, keywords = {cross section; AmBe; heavy water}, howpublished = {elektronická verze "online"}, language = {eng}, location = {Francie}, isbn = {978-2-7598-9106-1}, pages = {1-4}, publisher = {EDP Sciences, 2020}, title = {Validation of heavy water cross section using AmBe neutron source}, year = {2020} }
TY - JOUR ID - 1760256 AU - Košťál, Michal - Schulc, Martin - Novák, Evžen - Czakoj, Tomáš - Matěj, Zdeněk - Cvachovec, František - Mravec, Filip - Bohumil, Jánský - Leal, Luiz PY - 2020 TI - Validation of heavy water cross section using AmBe neutron source PB - EDP Sciences, 2020 CY - Francie SN - 9782759891061 KW - cross section KW - AmBe KW - heavy water N2 - Physical quantities derived from integral experiments can usually be measured much more accurately than that from differential nuclear data. The accurate knowledge of integral parameters provide excellent grounds for testing and tuning differential data such as, for instance, cross sections. Measurement of neutron leakage spectra with 252Cf neutron source located at sphere center is often used for integral experiments. While this type of experiments provide information for cross section tuning, however, care must be taken to avoid misleading interpretation, namely, at high energies due to the very low portion of high energy neutrons in 252Cf spectrum. This issue can be alleviated by the use of point source with different spectra shape. For that purpose one suitable candidate seems to be the AmBe neutron source which has a relatively high average energy and peak character of emitted neutrons. Indeed, AmBe seems an interesting option because the calculated leakage neutron spectra are not very sensitive to the input shape of the neutron spectra. Thus the neutron leakage spectra calculated using tabulated of International Organization for Standardization spectra is nearly the same as stilbene measured AmBe spectra as an input. ER -
KOŠŤÁL, Michal, Martin SCHULC, Evžen NOVÁK, Tomáš CZAKOJ, Zdeněk MATĚJ, František CVACHOVEC, Filip MRAVEC, Jánský BOHUMIL a Luiz LEAL. Validation of heavy water cross section using AmBe neutron source. Online. In \textit{ND 2019: International Conference on Nuclear Data for Science and Technology}. Francie: EDP Sciences, 2020, 2020, s.~1-4. ISBN~978-2-7598-9106-1. Dostupné z: https://dx.doi.org/10.1051/epjconf/202023918008.
|