STOJANOVIC, Z.S., A.D. DUROVIC, A.M. ASHRAFI, Z. KOUDELKOVA, O. ZITKA a L. RICHTERA. Highly sensitive simultaneous electrochemical determination of reduced and oxidized glutathione in urine samples using antimony trioxide modified carbon paste electrode. Sensors and Actuators B: Chemical. Lausanne: Elsevier, 2020, roč. 318, SEP, s. 128141-128152. ISSN 0925-4005. Dostupné z: https://dx.doi.org/10.1016/j.snb.2020.128141.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Highly sensitive simultaneous electrochemical determination of reduced and oxidized glutathione in urine samples using antimony trioxide modified carbon paste electrode
Autoři STOJANOVIC, Z.S., A.D. DUROVIC, A.M. ASHRAFI, Z. KOUDELKOVA, O. ZITKA a L. RICHTERA.
Vydání Sensors and Actuators B: Chemical, Lausanne, Elsevier, 2020, 0925-4005.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10405 Electrochemistry
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 7.460
Kód RIV RIV/00216224:14740/20:00121457
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1016/j.snb.2020.128141
UT WoS 000539189500001
Klíčová slova anglicky GSH; GSSG; Simultaneous determination; Modified carbon paste electrode; Square-wave voltammetry; Urine
Štítky ne MU, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 29. 4. 2021 12:27.
Anotace
A simple and reproducible electroanalytical sensor using antimony trioxide modified-carbon paste electrode (Sb2O3-CPE) as sensing element was employed for the first time for simultaneous determination of glutathione (GSH) and glutathione disulphide (GSSG). The electrochemical response of Sb2O3-CPE was characterized by cyclic voltammetry and square-wave voltammetry. Scanning electron microscopy (SEM), scanning electrochemical microscopy (SECM) and Raman mapping were used to characterize the morphology and surface modification. A significant enhancement in the peak current response of GSH and GSSG accompanied with a good separation of the peaks were obtained at the modified electrode compared to the bare CPE. GSH and GSSG exhibited well-defined oxidation peaks at +1.08 V and +1.36 V (vs. Ag/AgCl, 3 mol/L) in Britton-Robinson buffer at pH 6.0. Parameters such as used supporting electrolyte and its pH value, amplitude and frequency were optimized for square-wave voltammetric determination. Under optimal conditions, voltammetric responses were linear in the concentration range of 2-200 mu mol/L for GSH and GSSG. The limits of detection were 0.34 mu mol/L and 0.10 mu mol/L for GSH and GSSG, respectively. Moreover, the proposed sensor also showed good reproducibility, stability and selectivity. Finally, the proposed sensor was applied for the simultaneous determination of GSH and GSSG in urine samples with satisfactory results.
Návaznosti
90043, velká výzkumná infrastrukturaNázev: CIISB
VytisknoutZobrazeno: 26. 4. 2024 14:15