2021
SP3 Protocol for Proteomic Plant Sample Preparation Prior LC-MS/MS
MIKULÁŠEK, Kamil, Hana KONEČNÁ, David POTĚŠIL, Renata HOLÁNKOVÁ, Jan HAVLIŠ et. al.Základní údaje
Originální název
SP3 Protocol for Proteomic Plant Sample Preparation Prior LC-MS/MS
Autoři
MIKULÁŠEK, Kamil (203 Česká republika, domácí), Hana KONEČNÁ (203 Česká republika, domácí), David POTĚŠIL (203 Česká republika, domácí), Renata HOLÁNKOVÁ (203 Česká republika, domácí), Jan HAVLIŠ (203 Česká republika, domácí) a Zbyněk ZDRÁHAL (203 Česká republika, garant, domácí)
Vydání
Frontiers in Plant Science, Frontiers Research Foundation, 2021, 1664-462X
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10611 Plant sciences, botany
Stát vydavatele
Švýcarsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 6.627
Kód RIV
RIV/00216224:14740/21:00121574
Organizační jednotka
Středoevropský technologický institut
UT WoS
000631851900001
Klíčová slova anglicky
bottom-up; protein cleanup; Arabidopsis thaliana; sodium dodecyl sulfate removal; single-pot solid-phase-enhanced sample preparation; carboxylated magnetic beads; filter-aided sample preparation; mass spectrometry
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 10. 10. 2024 14:43, Ing. Martina Blahová
Anotace
V originále
Quantitative protein extraction from biological samples, as well as contaminants removal before LC-MS/MS, is fundamental for the successful bottom-up proteomic analysis. Four sample preparation methods, including the filter-aided sample preparation (FASP), two single-pot solid-phase-enhanced sample preparations (SP3) on carboxylated or HILIC paramagnetic beads, and protein suspension trapping method (S-Trap) were evaluated for SDS removal and protein digestion from Arabidopsis thaliana (AT) lysate. Finally, the optimized carboxylated SP3 workflow was benchmarked closely against the routine FASP. Ultimately, LC-MS/MS analyses revealed that regarding the number of identifications, number of missed cleavages, proteome coverage, repeatability, reduction of handling time, and cost per assay, the SP3 on carboxylated magnetic particles proved to be the best alternative for SDS and other contaminants removal from plant sample lysate. A robust and efficient 2-h SP3 protocol for a wide range of protein input is presented, benefiting from no need to adjust the amount of beads, binding and rinsing conditions, or digestion parameters.
Návaznosti
EF16_013/0001776, projekt VaV |
| ||
EF16_019/0000738, projekt VaV |
| ||
LM2018127, projekt VaV |
| ||
LM2018140, projekt VaV |
| ||
90127, velká výzkumná infrastruktura |
|