VRANA, Branislav, Jakub URÍK, Ganna FEDOROVA, Helena SVECOVA, Katerina GRABICOVA, Oksana GOLOVKO, Tomas RANDAK a Roman GRABIC. In situ calibration of polar organic chemical integrative sampler (POCIS) for monitoring of pharmaceuticals in surface waters. Environmental Pollution. OXFORD, OXON, ENGLAND: ELSEVIER SCI LTD, 2021, roč. 269, January 2021, s. 1-12. ISSN 0269-7491. Dostupné z: https://dx.doi.org/10.1016/j.envpol.2020.116121.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název In situ calibration of polar organic chemical integrative sampler (POCIS) for monitoring of pharmaceuticals in surface waters
Autoři VRANA, Branislav (703 Slovensko, garant, domácí), Jakub URÍK (703 Slovensko, domácí), Ganna FEDOROVA (203 Česká republika), Helena SVECOVA (203 Česká republika), Katerina GRABICOVA (203 Česká republika), Oksana GOLOVKO, Tomas RANDAK a Roman GRABIC (203 Česká republika).
Vydání Environmental Pollution, OXFORD, OXON, ENGLAND, ELSEVIER SCI LTD, 2021, 0269-7491.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10511 Environmental sciences
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 9.988
Kód RIV RIV/00216224:14310/21:00119171
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.envpol.2020.116121
UT WoS 000604429000048
Klíčová slova anglicky Aquatic pollution; Passive sampling; Sampling rate; Polar organic contaminants
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Michaela Hylsová, Ph.D., učo 211937. Změněno: 31. 8. 2021 22:18.
Anotace
POCIS is the most widely applied passive sampler of polar organic substances, because it was one of the first commercially available samplers for that purpose on the market, but also for its applicability for a wide range of substances and conditions. Its main weakness is the variability of sampling performance with exposure conditions. In our study we took a pragmatic approach and performed in situ calibration for a set of 76 pharmaceuticals and their metabolites in five sampling campaigns in surface water, covering various temperature and flow conditions. In individual campaigns, R-S were calculated for up to 47 compounds ranging from 0.01 to 0.63 L d(-1), with the overall median value of 0.10 L d(-1). No clear changes of R-S with water temperature or discharge could be found for any of the investigated substances. The absence of correlation of experimental R-S with physical-chemical properties in combination with the lack of mechanistic understanding of compound uptake to POCIS implies that practical estimation of aqueous concentrations from uptake in POCIS depends on compound-specific experimental calibration data. Performance of POCIS was compared with grab sampling of water in seven field campaigns comprising multiple sampling sites, where sampling by both methods was done in parallel. The comparison showed that for 25 of 36 tested compounds more than 50% of POCIS-derived aqueous concentrations did not differ from median of grab sampling values more than by a factor of 2. Further, for 30 of 36 compounds, more than 80% of POCIS data did not differ from grab sampling data more than by a factor of 5. When accepting this level of accuracy, in situ derived sampling rates are sufficiently robust for application of POCIS for identification of spatial and temporal contamination trends in surface waters.
Návaznosti
EF16_013/0001761, projekt VaVNázev: RECETOX RI
GX20-04676X, projekt VaVNázev: Holistická charakterizace expozice a potenciálních účinků komplexních směsí chemických látek ve vodním prostředí
Investor: Grantová agentura ČR, Holistická charakterizace expozice a potenciálních účinků komplexních směsí chemických látek ve vodním prostředí
LM2018121, projekt VaVNázev: Výzkumná infrastruktura RECETOX (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, RECETOX RI
VytisknoutZobrazeno: 1. 8. 2024 02:23