SEDLAČKOVÁ, Lenka, Lisa Emily MELYMUK a Branislav VRANA. Calibration of silicone for passive sampling of semivolatile organic contaminants in indoor air. Chemosphere. OXFORD: PERGAMON-ELSEVIER SCIENCE LTD, 2021, roč. 279, September 2021, s. 1-9. ISSN 0045-6535. Dostupné z: https://dx.doi.org/10.1016/j.chemosphere.2021.130536.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Calibration of silicone for passive sampling of semivolatile organic contaminants in indoor air
Autoři SEDLAČKOVÁ, Lenka (703 Slovensko, domácí), Lisa Emily MELYMUK (124 Kanada, domácí) a Branislav VRANA (703 Slovensko, garant, domácí).
Vydání Chemosphere, OXFORD, PERGAMON-ELSEVIER SCIENCE LTD, 2021, 0045-6535.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10511 Environmental sciences
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 8.943
Kód RIV RIV/00216224:14310/21:00119172
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.chemosphere.2021.130536
UT WoS 000659971200060
Klíčová slova anglicky Sampler calibration; Inhalation exposure; Persistent organic compounds; Model
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Michaela Hylsová, Ph.D., učo 211937. Změněno: 31. 8. 2021 22:24.
Anotace
Semivolatile organic compounds (SVOCs) are mostly man-made chemicals that distribute between the gas and solid phase in the environment. Many of them could pose harm to people and therefore it is important to know their concentrations in the indoor environment to evaluate the related risks. Inhalation exposure can be assessed using passive sampling. In this study, we employed silicone elastomer as a passive sampler for monitoring gaseous polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs) in indoor air. We performed a sampler calibration study in which samplers consisting of 0.5 mm thick silicone sheets with a total surface area of 300 cm(2) were exposed to indoor air in a university lecture theatre for up to 56 days. Uptake kinetics of SVOCs was studied by collecting 2 samplers every week. The results were used to develop a model based on mass transfer theory that can be used to estimate the air sampling rate R-S as a function of compound's molecular volume. We examined release kinetics of performance reference compounds that covered a broad range of silicone-air partition coefficient (log K-SA 5.95-9.49) and investigated a hypothesis of isotropic exchange kinetics, i.e. equality of rate constants for uptake and release, of SVOCs. PCBs and OCPs concentration in air calculated from contaminant amounts accumulated in passive samplers were in good agreement with those determined by active sampling running simultaneously during the entire study. The use of performance reference compounds is suitable for in situ passive sampler calibration.
Návaznosti
EF17_043/0009632, projekt VaVNázev: CETOCOEN Excellence
GA19-20479S, projekt VaVNázev: Prach jako významný zdroj expozice člověka endokrinním disruptorům ve vnitřním protředí
Investor: Grantová agentura ČR, Prach v prostředí jako důležitá expoziční cesta člověka působení endokrinních disruptorů
LM2018121, projekt VaVNázev: Výzkumná infrastruktura RECETOX (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, RECETOX RI
VytisknoutZobrazeno: 19. 7. 2024 23:09