2021
Sensitive determination of tetracycline antibiotics by liquid chromatography with fluorescence and mass spectrometric detection
KUBINYIOVÁ, Lenka, Ondřej PEŠ, Josef KUČERA, Jan JUŘICA, Ondřej ZENDULKA et. al.Základní údaje
Originální název
Sensitive determination of tetracycline antibiotics by liquid chromatography with fluorescence and mass spectrometric detection
Autoři
KUBINYIOVÁ, Lenka (203 Česká republika, domácí), Ondřej PEŠ (203 Česká republika, domácí), Josef KUČERA (203 Česká republika, domácí), Jan JUŘICA (203 Česká republika, domácí), Ondřej ZENDULKA (203 Česká republika, domácí), Pavel ŠMAK (203 Česká republika, domácí) a Petr TÁBORSKÝ (203 Česká republika, garant, domácí)
Vydání
22. ročník Školy hmotnostní spektrometrie, 2021
Další údaje
Jazyk
angličtina
Typ výsledku
Konferenční abstrakt
Obor
10609 Biochemical research methods
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Kód RIV
RIV/00216224:14110/21:00122331
Organizační jednotka
Lékařská fakulta
ISBN
978-80-88195-25-2
Klíčová slova anglicky
fluorescence; mass spectrometry; heavy water; tetracyclines
Změněno: 14. 9. 2021 10:38, doc. Mgr. Ondřej Peš, Ph.D.
Anotace
V originále
Tetracycline compounds present a broad spectrum of antibiotics widely used in medicine. Since their discovery they have been used in the treatment of human diseases as well as in veterinary applications. However, their overuse in food-producing animals may express an adverse effect on human health and even induce selective resistance. Selected antibiotics from the class of tetracyclines have been analyzed using liquid chromatography with fluorescence detection (LC-FLU) and LC with mass spectrometric detection (LC-MS) on a core-shell C18 column. As majority systems nowadays rely on reversed-phase columns with water being the main component of the mobile phase, a simple replacement of H 2 O with D 2 O in the mobile phase enhanced the sensitivity for selected compounds by 10–200%. MS was used to unambiguously identify the separated compounds and to locate the labile hydrogen sites. Another way to increase the fluorescence intensity lied in production of complex compounds of the tetracycline molecules and Mg 2+ ions. Such simple yet effective approaches improved limits of detection and sensitivity and may be selectively exploited (on demand) in the LC-FLU analysis of these compounds.
Návaznosti
MUNI/A/1192/2020, interní kód MU |
| ||
MUNI/A/1249/2020, interní kód MU |
| ||
MUNI/A/1266/2020, interní kód MU |
|