J 2020

Pilot study of the multicentre DISCHARGE Trial: image quality and protocol adherence results of computed tomography and invasive coronary angiography

RUBEIS, De., G. NAPP, A. E. SCHLATTMANN, P. GELEIJNS, J. LAULE et. al.

Základní údaje

Originální název

Pilot study of the multicentre DISCHARGE Trial: image quality and protocol adherence results of computed tomography and invasive coronary angiography

Autoři

RUBEIS, De., G. NAPP, A. E. SCHLATTMANN, P. GELEIJNS, J. LAULE, M. DREGER, H. KOFOED, K. SORGAARD, M. ENGSTROM, T. TILSTED, H. H. BOI, A. PORCU, M. COSSA, S. RODRIGUEZ-PALOMARES, J. F. VALENTE, F. X. ROQUE, A. FEUCHTNER, G. PLANK, F. STECHOVSKY, C. ADLA, T. SCHROEDER, S. ZELESNY, T. GUTBERLET, M.. WOINKE, M. KAROLYI, M. KARADY, J. DONNELLY, P. BALL, P. DODD, J. HENSEY, M. MANCONE, M. CECCACCI, A. BERZINA, M. ZVAIGZNE, L. SAKALYTE, G. BASEVICIUS, A. ILNICKA-SUCKIEL, M. KUSMIERZ, D. FARIA, R. GAMA-RIBEIRO, V. BENEDEK, I. BENEDEK, T. ADJIC, F. CANKOVIC, M. BERRY, C. DELLES, C. THWAITE, E. DAVIS, G. KNUUTI, J. PIETILA, M. KEPKA, C. KRUK, M. VIDAKOVIC, R. NESKOVIC, A. N. LECUMBERRI, I. GONZALES, I. D. RUZSICS, B. FISHER, M. DEWEY a M. FRANCONE

Vydání

European Radiology, New York, Springer, 2020, 0938-7994

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30230 Other clinical medicine subjects

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 5.315

UT WoS

000519659200020

Klíčová slova anglicky

Medical imaging; CT angiography; Angiography; coronary; Coronary artery disease; Trial protocols
Změněno: 7. 12. 2021 12:59, Bc. Hana Vladíková, BBA

Anotace

V originále

Objective To implement detailed EU cardiac computed tomography angiography (CCTA) quality criteria in the multicentre DISCHARGE trial (FP72007-2013, EC-GA 603266), we reviewed image quality and adherence to CCTA protocol and to the recommendations of invasive coronary angiography (ICA) in a pilot study. Materials and methods From every clinical centre, imaging datasets of three patients per arm were assessed for adherence to the inclusion/exclusion criteria of the pilot study, predefined standards for the CCTA protocol and ICA recommendations, image quality and non-diagnostic (NDX) rate. These parameters were compared via multinomial regression and ANOVA. If a site did not reach the minimum quality level, additional datasets had to be sent before entering into the final accepted database (FADB). Results We analysed 226 cases (150 CCTA/76 ICA). The inclusion/exclusion criteria were not met by 6 of the 226 (2.7%) datasets. The predefined standard was not met by 13 of 76 ICA datasets (17.1%). This percentage decreased between the initial CCTA database and the FADB (multinomial regression, 53 of 70 vs 17 of 75 [76%] vs [23%]). The signal-to-noise ratio and contrast-to-noise ratio of the FADB did not improve significantly (ANOVA, p = 0.20; p = 0.09). The CTA NDX rate was reduced, but not significantly (initial CCTA database 15 of 70 [21.4%]) and FADB 9 of 75 [12%]; p = 0.13). Conclusion We were able to increase conformity to the inclusion/exclusion criteria and CCTA protocol, improve image quality and decrease the CCTA NDX rate by implementing EU CCTA quality criteria and ICA recommendations.