Upgrade of The Langendorff Apparatus Using The Infrared Thermo-Control System and An Intelligent Heater
SKOPALÍK, Josef, Jiří SEKORA, Martin PEŠL, Markéta BÉBAROVÁ, Olga ŠVECOVÁ et. al.Základní údaje
Originální název
Upgrade of The Langendorff Apparatus Using The Infrared Thermo-Control System and An Intelligent Heater
Autoři
SKOPALÍK, Josef (203 Česká republika, garant), Jiří SEKORA (203 Česká republika), Martin PEŠL (203 Česká republika, domácí), Markéta BÉBAROVÁ (203 Česká republika, domácí), Olga ŠVECOVÁ (203 Česká republika, domácí), Tomáš PARÁK (203 Česká republika), Vratislav ČMIEL (203 Česká republika), Ivo PROVAZNÍK (203 Česká republika), Edita JEKLOVÁ (203 Česká republika) a Josef MAŠEK (203 Česká republika)
Vydání
Lékař a technika, Praha, Czech Society for Biomedical Engineering and Medical Informatics, 2020, 0301-5491
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
30105 Physiology
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Kód RIV
RIV/00216224:14110/20:00123174
Organizační jednotka
Lékařská fakulta
Klíčová slova anglicky
Langendorff Apparatus; pig heart; infrared; thermo-control; heater
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 8. 12. 2021 14:12, doc. MUDr. Markéta Bébarová, Ph.D.
Anotace
V originále
Biological experiments involving isolated organs and tissues demand precise temperature monitoring and regulation. An automatic temperature control system was proposed and optimised on real isolated swine hearts and the prototype is described in this work. The traditional Langendorff apparatus consists of a heart holder, a reservoir of perfusion solution flowing to aortic cannula and a heating bath allowing passive heat transfer to the reservoir of perfusion solution. The commercial infrared camera FLIR T62101 was added to this basic set-up and used for very precise monitoring of the temperature kinetic of the organ and connected with an electronic feedback loop, which allowed real-time and precise regulation of heat transfer from the heating bath to the perfusion solution and in turn indirectly to the heart tissue. This provides real time control and active regulation of the myocardial tissue temperature. The infrared camera was tested in several modes and several variants of detection were optimised for ideal measurement of the region of interest of the ex vivo organ. The kinetics of the temperature changes and temperature stability of the tissue were recorded and calibrated by external electronic thermometers (type Pt100, inserted in tissue). The time lapse from the hang-up of the hypo termed organ (30 °C) until optimal warming (37 °C) was less than eight minutes in the final instrument prototype. The final stability of the 37 °C tissue temperature was approved; the temperature fluctuation of left ventricle tissue was characterised as 36.8 ± 0.5 °C. This upgraded traditional instrument could be used in specific preclinical and clinical transplantation and analytical projects in future.