MLČOCHOVÁ, Hana, Lenka MICHALCOVÁ a Zdeněk GLATZ. Extending the application potential of capillary electrophoresis/frontal analysis for drug-plasma protein studies by combinating it with mass spectrometry detection. Electrophoresis. Wiley, 2022, roč. 43, 9-10, s. 955-963. ISSN 0173-0835. Dostupné z: https://dx.doi.org/10.1002/elps.202100301.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Extending the application potential of capillary electrophoresis/frontal analysis for drug-plasma protein studies by combinating it with mass spectrometry detection
Autoři MLČOCHOVÁ, Hana (203 Česká republika, garant, domácí), Lenka MICHALCOVÁ (203 Česká republika, domácí) a Zdeněk GLATZ (203 Česká republika, domácí).
Vydání Electrophoresis, Wiley, 2022, 0173-0835.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.900
Kód RIV RIV/00216224:14310/22:00125154
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1002/elps.202100301
UT WoS 000745514300001
Klíčová slova česky kapilární elektroforéza; CE-FA; MS; afinitní iterakce
Klíčová slova anglicky capillary electrophoresis; CE-FA; MS; affinity interaction
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 1. 6. 2022 13:41.
Anotace
CE/frontal analysis (CE/FA) is probably one of the most frequently used modes of CE for studying affinity interactions. It is typically performed with classic UV-Vis detection that suffers from low concentration sensitivity. To overcome this limitation, the applicability of CE/FA in combination with ESI-MS detection for the investigation of drug–HSA interactions was demonstrated. The developed new method combines the advantages of CE/FA, such as low sample consumption and no labeling or immobilization of interacting partners, with the benefits of MS detection, such as higher selectivity and sensitivity; moreover, it can be used for molecules lacking a fluorophore or chromophore. The binding parameters of tolbutamide (TL) and glimepiride (GLP), first- and second-generation antidiabetics that differ strongly in their solubility in aqueous solutions, were investigated by this CE/FA-MS method. This method, in contrast to the CE/FA method with the most commonly used UV-Vis detection, is more sensitive; an almost three times lower LOD was reached. The binding parameters of TL and GLP were investigated by this CE/FA-MS method and compared with the literature data. The binding constant value of TL obtained by UV-Vis detection was lower than the value obtained by the method hyphenated with MS detection, which is probably given by the influence of the ESI parameters on the stability of drug–HSA complex. In addition, the ratio of TL and HSA concentrations was divergent in both of the experimental approaches. Finally, it can be concluded that both detection methods have their strengths and weaknesses.
Návaznosti
GA19-08358S, projekt VaVNázev: Nové přístupy pro studium afinitních interakcí založené na kapilární elektroforéze
Investor: Grantová agentura ČR, Nove přístupy pro studium afinitních interakcí založené na kapilární elektroforéze
VytisknoutZobrazeno: 27. 4. 2024 04:34