MLČOCHOVÁ, Hana, Ratih RATIH, Lenka MICHALCOVÁ, Hermann WÄTZIG, Zdeněk GLATZ a Matthias STEIN. Comparison of mobility shift affinity capillary electrophoresis and capillary electrophoresis frontal analysis for binding constant determination between human serum albumin and small drugs. Electrophoresis. Wiley, 2022, roč. 43, 16-17, s. 1724-1734. ISSN 0173-0835. Dostupné z: https://dx.doi.org/10.1002/elps.202100320.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Comparison of mobility shift affinity capillary electrophoresis and capillary electrophoresis frontal analysis for binding constant determination between human serum albumin and small drugs
Název česky Srovnání metod msACE a CE-FA
Autoři MLČOCHOVÁ, Hana (203 Česká republika, domácí), Ratih RATIH (276 Německo), Lenka MICHALCOVÁ (203 Česká republika, domácí), Hermann WÄTZIG (276 Německo), Zdeněk GLATZ (203 Česká republika, domácí) a Matthias STEIN (garant).
Vydání Electrophoresis, Wiley, 2022, 0173-0835.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.900
Kód RIV RIV/00216224:14310/22:00129017
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1002/elps.202100320
UT WoS 000821928600001
Klíčová slova česky msACE; CE-FA; afinitní interakce
Klíčová slova anglicky msACE; CE-FA; affinity interaction
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 6. 12. 2022 10:56.
Anotace
In this study, two capillary electrophoresis–based ligand binding assays, namely, mobility shift affinity capillary electrophoresis (ms-ACE) and capillary electrophoresis-frontal analysis (CE-FA), were applied to determine binding parameters of human serum albumin toward small drugs under similar experimental conditions. The substances S-amlodipine (S-AML), lidocaine (LDC), l-tryptophan (l-TRP), carbamazepine (CBZ), ibuprofen (IBU), and R-verapamil (R-VPM) were used as the main binding partners. The scope of this comparative study was to estimate and compare both the assays in terms of their primary measure's precision and the reproducibility of the derived binding parameters. The effective mobility could be measured with pooled CV values between 0.55% and 7.6%. The precision of the r values was found in the range between 1.5% and 10%. Both assays were not universally applicable. The CE-FA assay could successfully be applied to measure the drugs IBU, CBZ, and LDC, and the interaction toward CBZ, S-AML, l-TRP, and R-VPM could be determined using ms-ACE. The average variabilities of the estimated binding constants were 64% and 67% for CE-FA and ms-ACE, respectively.
Anotace česky
Pro studium interakcí plazmatických bílkovin s léčivy byly srovnány dvě metody založené na kapilární elektrovoréze - msACE a CE-FA.
Návaznosti
GA19-08358S, projekt VaVNázev: Nové přístupy pro studium afinitních interakcí založené na kapilární elektroforéze
Investor: Grantová agentura ČR, Nove přístupy pro studium afinitních interakcí založené na kapilární elektroforéze
VytisknoutZobrazeno: 23. 7. 2024 17:27