Další formáty:
BibTeX
LaTeX
RIS
@article{1837301, author = {Beniczky, S. and Wiebe, S. and Jeppesen, J. and Tatum, W.O. and Brázdil, Milan and Wang, Y.P. and Herman, S.T. and Ryvlin, P.}, article_location = {Hoboken}, article_number = {3}, doi = {http://dx.doi.org/10.1111/epi.16818}, keywords = {algorithms; automated detection; epilepsy; seizure detection; wearable devices}, language = {eng}, issn = {0013-9580}, journal = {Epilepsia}, title = {Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology}, url = {https://onlinelibrary.wiley.com/doi/10.1111/epi.16818}, volume = {62}, year = {2021} }
TY - JOUR ID - 1837301 AU - Beniczky, S. - Wiebe, S. - Jeppesen, J. - Tatum, W.O. - Brázdil, Milan - Wang, Y.P. - Herman, S.T. - Ryvlin, P. PY - 2021 TI - Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology JF - Epilepsia VL - 62 IS - 3 SP - 632-646 EP - 632-646 PB - Wiley-Blackwell SN - 00139580 KW - algorithms KW - automated detection KW - epilepsy KW - seizure detection KW - wearable devices UR - https://onlinelibrary.wiley.com/doi/10.1111/epi.16818 N2 - The objective of this clinical practice guideline (CPG) is to provide recommendations for healthcare personnel working with patients with epilepsy on the use of wearable devices for automated seizure detection in patients with epilepsy, in outpatient, ambulatory settings. The Working Group of the International League Against Epilepsy (ILAE) and the International Federation of Clinical Neurophysiology (IFCN) developed the CPG according to the methodology proposed by the ILAE Epilepsy Guidelines Working Group. We reviewed the published evidence using The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement and evaluated the evidence and formulated the recommendations following the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. We found high level of evidence for the accuracy of automated detection of generalized tonic-clonic seizures (GTCS) and focal-to-bilateral tonic-clonic seizures (FBTCS) and recommend the use of wearable automated seizure detection devices for selected patients when accurate detection of GTCS and FBTCS is recommended as a clinical adjunct. We also found a moderate level of evidence for seizure types without GTCS or FBTCS. However, it was uncertain whether the detected alarms resulted in meaningful clinical outcomes for the patients. We recommend using clinically validated devices for automated detection of GTCS and FBTCS, especially in unsupervised patients, where alarms can result in rapid intervention (weak/conditional recommendation). At present, we do not recommend clinical use of the currently available devices for other seizure types (weak/conditional recommendation). Further research and development are needed to improve the performance of automated seizure detection and to document their accuracy and clinical utility. ER -
BENICZKY, S., S. WIEBE, J. JEPPESEN, W.O. TATUM, Milan BRÁZDIL, Y.P. WANG, S.T. HERMAN a P. RYVLIN. Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology. \textit{Epilepsia}. Hoboken: Wiley-Blackwell, 2021, roč.~62, č.~3, s.~632-646. ISSN~0013-9580. Dostupné z: https://dx.doi.org/10.1111/epi.16818.
|