KUBÁŇ, Petr, Věra DOSEDĚLOVÁ, Kert MARTMA, Indrek RANNAMA, Karmen REINPOLD a Ruth SHIMMO. Sub-Minute Analysis of Lactate from a Single Blood Drop Using Capillary Electrophoresis with Contactless Conductivity Detection in Monitoring of Athlete Performance. Molecules. MDPI, 2021, roč. 26, č. 19, s. 5817-5825. ISSN 1420-3049. Dostupné z: https://dx.doi.org/10.3390/molecules26195817.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Sub-Minute Analysis of Lactate from a Single Blood Drop Using Capillary Electrophoresis with Contactless Conductivity Detection in Monitoring of Athlete Performance
Autoři KUBÁŇ, Petr (garant), Věra DOSEDĚLOVÁ (203 Česká republika, domácí), Kert MARTMA, Indrek RANNAMA, Karmen REINPOLD a Ruth SHIMMO.
Vydání Molecules, MDPI, 2021, 1420-3049.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10608 Biochemistry and molecular biology
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.927
Kód RIV RIV/00216224:14740/21:00124349
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.3390/molecules26195817
UT WoS 000717228700001
Klíčová slova anglicky capillary electrophoresis; lactate; blood plasma separation; CE-(CD)-D-4; training assessment
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 4. 3. 2022 14:24.
Anotace
A simple and fast method for the analysis of lactate from a single drop of blood was developed. The finger-prick whole blood sample (10 mu L) was diluted (1:20) with a 7% (w/v) solution of [tris(hydroxymethyl)methylamino] propanesulfonic acid and applied to a blood plasma separation device. The device accommodates a membrane sandwich composed of an asymmetric polysulfone membrane and a supporting textile membrane that allows the collection of blood plasma into a narrow glass capillary in less than 20 s. Separated and simultaneously diluted blood plasma was directly injected into a capillary electrophoresis instrument with a contactless conductivity detector (CE-(CD)-D-4) and analyzed in less than one minute. A separation electrolyte consisted of 10 mmol/L l-histidine, 15 mmol/L dl-glutamic acid, and 30 mu mol/L cetyltrimethylammonium bromide. The whole procedure starting from the finger-prick sampling until the CE-(CD)-D-4 analysis was finished, took less than 5 min and was suitable for monitoring lactate increase in blood plasma during incremental cycling exercise. The observed lactate increase during the experiments measured by the developed CE-(CD)-D-4 method correlated well with the results from a hand-held lactate analyzer (R = 0.9882). The advantage of the developed CE method is the speed, significant savings per analysis, and the possibility to analyze other compounds from blood plasma.
VytisknoutZobrazeno: 12. 7. 2024 13:04